1
2
1. Place generator on elevated platform such as table or desk.
2. Using a Phillips-head screwdriver (not included), remove the
service panel by unscrewing the three Phillips-head screws (Fig.
17) along the upper edge.
3. The carburetor (Fig. 18 - 1) can be accessed from the backside
of the generator between the engine and the air filter. Locate the
transparent tube (Fig. 18 - 2) from the carburetor that extends
down through the bottom of the generator.
4. Prepare an approved gasoline-storage container and direct the
end of the drain tube into the container.
5. Open up the carburetor drain screw (Fig. 18 - 3) with a flat-
head screwdriver (not included) and drain out any gasoline that
has built up inside the carburetor through the drain tube into the
approved gasoline-storage container.
6. Once the fuel has drained, tighten the drain screw with the
screwdriver.
NOTE:
Make sure to drain your carburetor before storing the gen-
erator for long periods of time.
7. Reinstall the service panel.
DRAINING THE CARBURETOR
We recommended draining the carburetor after every use (not necessary if the generator is shut off using the
“FUEL OFF” option), and before storing the generator.
Draining the carburetor can prevent the fuel from clogging
up the carburetor and preventing the generator from starting.
MAINTENANCE
Fig. 17
Fig. 18
3
30
Содержание DF250i
Страница 46: ...NOTES 46...