ECO-MODE SWITCH
This generator is equipped with an Eco-Mode Idle Control Switch. Engaging this switch allows the system to regu-
late the engine speed and automatically adjust its fuel consumption to match the required load. When the electrical
load changes, the generator engine will automatically speed up and slow down as needed. This reduces fuel con-
sumption and noise levels, while extending runtime and engine’s lifespan.
Keep this switch engaged ONLY when the power load requirement is LESS THAN
1500W / 1350W
(75% of the rated
watts). Do not engage the Eco-Mode Switch when the total load is more than 1500W / 1350W. The generator engine
must run at full speed to supply power for anything over 1500W / 1350W.
PARALLEL OPERATION
The parallel connection ports allow you to connect two WEN generators to increase the total available electrical
power. The
WEN Parallel Connection Kit
can be purchased from
wenproducts.com
. Follow the instructions in-
cluded with your parallel connection kit for proper installation and operation.
IN CASE OF OVERLOAD
If your generator becomes overloaded from too much drawn wattage, the overload indicator (red) on the control
panel will light up, and the overload reset button on your control panel may activate and cut off the output. When
an overload occurs, reduce the load by turning off and unplugging your electronic device(s), then press the reset
button to reset your generator. If no power is produced after resetting, restart your generator.
• 4% to 10% over rated watts: overload light will flash to indicate overload
• 10% to 18% over rated watts: overload light will stay on for 16 seconds, output will be cut off.
• More than 18% over rated watts: overload light will stay on for 3 seconds, output will be cut off.