background image

12

PREPARATION

TO ADD OIL:

1. Place the generator on a level surface. Make sure the engine is 

OFF before adding or checking oil. 

1

The following section describes the necessary steps to prepare the generator for use. If you are unsure about how to 

perform any of the steps please call 

1-(800) 232-1195

 M-F 8-5 CST for customer service. Failure to perform these 

steps properly can damage the generator or shorten its life. 

STEP 1 - ADD / CHECK OIL

The generator is shipped without oil. User must add the proper amount of oil before operating the generator for the 

first time. The oil capacity of the engine crankcase is 

17.1 fl. oz.

 (0.5 L).

•  30W Engine Oil 

Temperatures above 40°F

•  10W-30 Engine Oil 

Temperatures between 0°F - 40°F

•  Synthetic 5W-30 Engine Oil 

All temperature ranges

ENGINE OIL RECOMMENDATIONS

Select good quality detergent oil bearing the American Petroleum Institute (API) service classifications 

SJ, SL, or SM  (synthetic oils may be used). Select the SAE viscosity grade of oil that matches the 

expected operating temperature. 

CAUTION!

 Keep the generator level. Tilting the generator to 

assist in filling will cause oil to flow into the wrong areas of the 

engine and cause damage.  

1. Open the oil access cover (Fig. 2 - 1), remove and wipe the oil 

dipstick with a clean rag. Insert the dipstick into the oil fill opening 

without screwing it in.

2. Remove the dipstick to check the oil mark on the dipstick (Fig. 

3). Add oil if the oil mark covers less than one half of the dipstick.

3. Slowly add oil and repeat step 2 until the oil mark reaches to the 

top of dipstick (or when you can see the oil coming halfway up the 

oil fill threads). Do not overfill the crankcase.

4. Wipe clean any oil leaks and firmly tighten the dipstick.

CAUTION!

 For subsequent operation, the oil 

level should be checked before each use, or 

after every 8 hours of operation. The gen-

erator is equipped with a low-oil sensor and 

will not start without a sufficient amount of 

oil. Follow the instructions on the next page 

to check the oil level.

Fig. 1 

Fig. 2 

Synthetic 5W-30

30W

10W-30

°F
°C

-20

0

20

32

40

60

80

100

40

20

0

-20

-10

10

-30

30

Содержание 56235i

Страница 1: ...ouble free performance Pay close attention to the rules for safe operation warnings and cautions If you use your tool properly and for its intended purpose you will enjoy years of safe reliable servic...

Страница 2: ...arting Your Generator 15 Using Your Generator 18 Stopping Your Generator 22 Maintenance 23 Transportation Storage 28 Troubleshooting Guide 29 Wire Diagram 30 Exploded View Parts List 31 Warranty State...

Страница 3: ...Weight 39 lbs Product Dimensions 17 3 x 11 5 x 17 7 GENERATOR Engine Type 4 stroke OHV single cylinder with forced air cooling system Engine Displacement 79cc Engine Speed 4800 RPM Fuel Tank Capacity...

Страница 4: ...95 M F 8 5 CST you will be asked to provide the following generator information when calling Generator Model Number 56235i Date of Purchase _______________________________________________ Purchased Fr...

Страница 5: ...ols is to attract your attention to possible dangers The safety symbols and their explanations deserve your careful attention and understanding The safety warnings do not by themselves eliminate any d...

Страница 6: ...soline Do not operate near open flame heat or any other ignition source Do not smoke near the generator Always operate on a firm level surface Always turn generator off before refueling Allow generato...

Страница 7: ...ould only be performed by a qualified technician Do not use receptacles or cords that show signs of damage such as broken or cracked insulation 4 Use a ground fault circuit interrupter GFCI in highly...

Страница 8: ...he generator that be come hot during use 8 Turn off all connected electrical devices before stop ping the generator 9 Always turn generator off before refueling Allow generator to cool for at least 2...

Страница 9: ...accessories Do not discard the packaging until everything is removed Check the packing list below to make sure you have all of the parts and accessories If any part is missing or broken please contac...

Страница 10: ...to the fol lowing diagrams to become familiarized with all the parts and controls of your Generator The components will be referred to later in the manual for assembly and operation instructions GENE...

Страница 11: ...power 4 5V USB Port 1A 2 1A for charging various electronic devices 5 Circuit Breaker Press to reset 6 Grounding Nut Ground the generator to reduce the risk of electric shock Refer to Ground the Gener...

Страница 12: ...the SAE viscosity grade of oil that matches the expected operating temperature CAUTION Keep the generator level Tilting the generator to assist in filling will cause oil to flow into the wrong areas...

Страница 13: ...ar open flame heat or any other ignition source Do not smoke near the generator Always operate on a firm level surface Always turn generator off before refueling Allow generator to cool for at least 2...

Страница 14: ...fuel system on this generator may be affected by opera tion at high altitudes Proper operation can be ensured by installing an altitude kit at altitudes higher than 2000 feet above sea level At eleva...

Страница 15: ...u use a generator correctly CO may leak into the home ALWAYS use a battery powered or battery backup CO alarm in the home If you start to feel sick dizzy or weak after the generator has been running m...

Страница 16: ...vel of oil in the crankcase Add oil if necessary refer to Add Check Oil on page 12 3 Check there is sufficient level of gasoline in the fuel tank Add fuel if necessary refer to Add Gasoline on page 13...

Страница 17: ...two WEN generators to increase the total available electrical power The Parallel Connection Kit can be purchased from wenproducts com Follow the instructions included with your WEN parallel connectio...

Страница 18: ...tion Find the wattage information of each device you plan to connect The information should be listed on the device or in its instruction manual or you may refer to page19 Table 2 The wattage can be c...

Страница 19: ...HP 1500 3000 Window Air Conditioner 1200 1800 Saw Miter 1200 1200 Microwave 1000 0 Well Water Pump 1000 1000 Sump Pump 800 1200 Refrigerator Freezer 800 1200 Furnace Blower 800 1300 Computer 800 0 El...

Страница 20: ...erload the generator or individual panel receptacles If an overload occurs the overload indication light red will activate If it is flashing turn off and unplug one load If it is solid not flashing th...

Страница 21: ...000 6000 150 100 60 NR NR 30 3600 7200 125 65 NR NR NR 40 4800 9600 90 NR NR NR NR WARNING Generator should only be connected to electrical devices either directly or with an extension cord NEVER CONN...

Страница 22: ...uickly e g for refueling moving the generator etc by turning the engine switch to the OFF position Fig 16 but this option will let fuel remain in the carburetor Be sure to drain the carburetor see pag...

Страница 23: ...nded Maintenance Schedule Clean change more often under dusty conditions or operating under heavy load IMPORTANT GENERATOR MAINTENANCE TIPS Drain your carburetor after each use and before storage to p...

Страница 24: ...iate dispenser slowly add more oil Repeat step 3 until the oil mark reaches the top of the dipstick and you can see oil coming up the threads of the oil fill Do not over fill the crankcase 5 Reinstall...

Страница 25: ...r porcelain is cracked replace with a NGK BP5H Torch E5T spark plug Part No 56202i 102 available at wenproducts com 5 If re using the spark plug use a wire brush to clean any dirt from around the spar...

Страница 26: ...filter element and close the air filter cover Close the air filter cover Replace the side cover and secure it with the screws Reinstall the oil access panel CAUTION Running the engine with a dirty da...

Страница 27: ...ffler and secure it in place with the screw 7 Replace the muffler cover and secure it with the six screws DRAINING THE FUEL TANK 1 Prepare an approved gasoline storage container Make sure the vacuum r...

Страница 28: ...h for 20 to 30 minutes Plug in a small load in to ensure there is proper power output PRODUCT DISPOSAL Do not dispose of a used generator or parts with your household waste This product contains elect...

Страница 29: ...reset it Bad connecting cords wires Check the power cords and extension cords Do not use if any cord is damaged Replace damaged cords immediately Bad electrical device con nected to the generator Try...

Страница 30: ...WIRING DIAGRAM 30...

Страница 31: ...EXPLODED VIEW PARTS LIST GENERATOR 31...

Страница 32: ...p 2 9 7 x 8 1 29 56202i 029 Fuel Strainer 1 30 56202i 030 Rubber Pad 2 31 56202i 031 Fuel Tank 1 NO PART NO DESCRIPTION QTY 32 56202i 032 Rubber Washer 1 33 56202i 033 Lock Nut 1 34 56202i 034 Fuel Ta...

Страница 33: ...EXPLODED VIEW PARTS LIST ENGINE 33...

Страница 34: ...2i 130 Oil Tube 1 31 56202i 131 Air Filter Hose 1 32 56202i 132 Clamp 1 33 56202i 133 Gasket Cylinder Head 1 34 56202i 134 Dowel Pin 8x12 4 NO PART NO DESCRIPTION QTY 35 56202i 135 Push Rod 2 36 56202...

Страница 35: ...EXPLODED VIEW PARTS LIST 35 CONTROL PANEL...

Страница 36: ...03i 005 5 Reset Button 1 6 56203i 005 6 DC Breaker 8A 1 7 56203i 005 7 Oil Level LED Yellow 1 CONTROL PANEL 36 NO PART NO DESCRIPTION QTY 8 56203i 005 8 Overload LED Red 1 9 56203i 005 9 Output LED Gr...

Страница 37: ...o be sent to WEN before the replacements can be shipped out turning a product for warranty service the shipping charges must be prepaid by the purchaser The product must be shipped in its original con...

Страница 38: ...NOTES 38...

Страница 39: ...NOTES 39...

Страница 40: ...THANKS FOR REMEMBERING V 2020 02 04...

Отзывы: