STARTING YOUR GENERATOR
Before starting the generator, check the following:
1. Place the generator outside on a dry, level surface. Allow at least
two feet of clearance on all sides of the generator.
2. Make sure all electrical devices are unplugged from the genera-
tor during ignition. Otherwise it will be difficult for the engine to
start.
3. To maximize safety, check that the generator is properly ground-
ed (see “GROUND THE GENERATOR” section).
4. Check there is sufficient level of oil in the crankcase. Add oil if
necessary (refer to “ADD/CHECK OIL” section).
5. Make sure there is sufficient level of gasoline in the fuel tank.
Add fuel if necessary (refer to “ADD/CHECK FUEL” section).
To start the generator, perform the following steps:
1. Turn the ECO-MODE (Fig. 8 - 1) switch to “OFF” during starting.
2. Open the vacuum relief valve (Fig. 9 ) on top of fuel cap by rotat-
ing it clockwise to the “ON” position. This will allow fuel to flow.
3. Turn the 3-in-1 dial switch (Fig. 8 - 2) to the “CHOKE” position.
4. Place one hand on the generator to hold it in place, and pull on
the recoil starter handle slowly until a slight resistance is felt (Fig.
10). Then pull quickly to start the engine. Return cord gently into
the machine. Never allow the cord to snap back.
5. If engine fails to start, repeat step 4.
NOTE:
After repeated failed attempts to start the engine, please
consult the troubleshooting guide before attempting again. If prob-
lems persist please call (800) 232-1195 M-F 8-5 CST.
Before starting the generator, make sure you have read and performed the steps in the “Generator Prepara-
tion” section of this manual. If you are unsure about how to perform any of the steps in this manual please
call (800) 232-1195 M-F 8-5 CST for customer service.
6. After the engine has started, turn the 3-in-1 switch (Fig. 8 - 2) to
the “RUN” position. The output indicator (green) will light up.
7. Allow the generator to run for several minutes before attempt-
ing to connect any electrical devices. This allows the generator to
stabilize its speed and temperature.