REMOVE THE STYROFOAM BLOCKS (Fig. 1)
Styrofoam blocks are installed around the motor to protect it from
shipping damage. They must be removed before operation. Lift
up the filter lock clips on the back of the machine to remove the
outer filter and inner filter and remove the styrofoam. Replace
the inner and outer filters and close the lock clips.
ATTACHING THE RUBBER FEET
The four sticky rubber feet can be attached onto the base of the
unit as necessary.
INSTALLING THE HANGERS (Fig. 2)
Thread a mounting hanger (Fig. 2 - 31) into a mounting hole on
the top of the air filter cabinet. Rotate the hanger clockwise to
fully tighten it into the hole. Repeat for all four hangers.
INSTALLING THE BRACKETS (Fig. 2)
Attach the mounting bracket (Fig. 2 - 12) using two M6 x 4.8 bolts
(Fig. 2 - 10), two M6 lock washers (Fig. 2 - 2) and two M6 flat
washers (Fig. 2 - 11). Tighten bolts securely using an M10 socket
or wrench (not included). Repeat for all four mounting brackets.
CEILING MOUNTING (Fig. 3)
WARNING:
Only anchor the air filtration system to
building structures capable of holding at least 100 lbs.
Do not mount the air filtration system to non-structural
surfaces such as dry wall or false ceiling grids. The unit must be
situated at least 7 feet above the floor and at least 3 feet (1 m) away
from any heating, cooling, or air circulation vents.
1. Install the wood screw hooks (Fig. 2 - 1) into the building sup-
port structure.
NOTE:
Wood screw hooks and chains used for
ceiling mounting are not included. Make sure to use chain and
hooks that are properly rated for hanging this unit.
2. Place a chain (Fig. 2 - 2) on each wood screw hook.
12
11
10
2
31
ASSEMBLY AND ADJUSTMENTS
The air filtration system is designed to circulate air and filter wood and other non-metallic dust. To achieve the best
performance possible, it is important to consider how and where to place the unit. When selecting a site, make sure
there is a suitable power source nearby. The use of an extension cord is not recommended.
Fig. 1
Fig. 2
Fig. 3
WARNING:
To prevent serious injury from accidental operation, make sure the power cord is discon-
nected from the power source and the tool is switch to OFF before assembly or making any adjustments.
3
1
2
3. Attach the chain onto the mounting hangers (Fig. 2 - 3). The four mounting brackets can also be used for mount-
ing the unit onto the ceiling or wall.
4. Make sure the unit is horizontally level, and is at least 7 feet above the floor. If it is not, remove the unit and adjust
the length of the chain as needed. Then remount the unit.
7