background image

OPERATION

ASSEMBLY

STARTING THE COMPRESSOR

1. Follow all instructions in the assembly guidelines outlined above before attempting to start the compressor. Do 
not start the generator until the air filter, oil cap breather and oil have been properly installed.

2. Inspect the machine components to make sure that there are no damaged or worn parts. Replace any damaged 
parts immediately. Only repair using identical replacement parts. 

3. Check that the pressure switch is turned to OFF position and the tank drain valve is closed.

4. Connect an air hose (not included) to the air line inlet (Fig. 4 - 1). Make sure the air hose is rated high enough to 
handle the max PSI of the compressor.

5. Connect the electrical plug to a power supply. NOTE: the compressor must be at least one foot from any wall or 
obstruction in a well-ventilated area in order to maximize proper air flow. Do not cover the compressor.

6. Turn the pressure switch (Fig. 4 - 3) to the ON/AUTO position to allow the compressor to automatically start up 
and shut down depending on its need for air. NOTE: make sure this switch is set to OFF before unplugging, plug-
ging in, or storing the compressor.

INSTALLING THE WHEELS

Insert  bolt  M10X1.25X57  into  the  wheel  through  the  wheel 
bracket and 10mm flat washer, then tighten with M10X1.25 hex 
nut. Repeat for both wheels.

INSTALLING THE AIR FILTER

Remove the plastic plug. Install the air filter (Fig. 2 - 1) before 
starting the air compressor.

INSTALLING THE OIL CAP BREATHER

Remove the plastic plug from the oil fill port (Fig. 2 - 3). Slowly 
fill with the provided semi-synthetic oil while observing the oil 
gauge (Fig. 2 - 4). Fill until the oil lands in the middle of the red 
circle between A and B (Fig. 3). Install the oil cap breather (Fig. 
2 - 2) before starting the air compressor.

WARNING: 

Be sure to fill with semi-synthetic com-

pressor oil before starting the machine. 

Fig. 1

Fig. 2

Fig. 3

1

2

3

4

A

B

REFILLING OIL

Check the oil level before each operation. When the oil level is below B, refill the 
compressor with semi-synthetic compressor oil until the oil reaches the center of 
the red circle in the oil gauge. Do not let oil level exceed A (Fig. 3). 

8

Содержание 2287

Страница 1: ...ged trouble free performance Pay close attention to the rules for safe operation warnings and cautions If you use your tool properly and for intended purpose you will enjoy years of safe reliable service IMPORTANT NEED HELP CONTACT US Have product questions Need technical support Please feel free to contact us at 800 232 1195 techsupport wenproducts com WENPRODUCTS COM M F 8AM 5PM CST 4000049 For ...

Страница 2: ...0 Hz 3 Wire 6 Gallon 125 PSI 95 PSIG 125 PSIG Quick Coupler 1 4 NPT 3 2 CFM at 90 PSI 4 2 CFM at 40 PSI 50 Single Stage 23 6 x 13 8 x 22 8 inches 57 3 pounds 2 TABLE OF CONTENTS Technical Data 2 3 4 6 7 8 8 10 11 12 14 General Safety Rules Specific Safety Rules for Compressors Know Your Compressor Operation Assembly Troubleshooting Warranty Parts List Exploded View Maintenance Electrical Informati...

Страница 3: ...ying alert and knowing how your item works SAVE THESE SAFETY INSTRUCTIONS WARNING Read all safety warnings and all instructions Failure to follow the warnings and instruc tions may result in electric shock fire and serious injury To avoid mistakes and serious injury do not plug in your tool until the following steps have been read and understood WORK AREA SAFETY 1 Keep work area clean and well lit...

Страница 4: ...s Check for misalignment of moving parts jamming breakage improper mounting or any other conditions that may affect the tool s operation Do not use the power tool if the switch does not turn ON OFF Any part that is damaged should be properly repaired or replaced before use 3 Do not force the tool to do a job for which it was not designed Use the correct power tool and accessories and follow the in...

Страница 5: ...ile plugged in Unplug compressor and detach hoses and accessories after use 12 Drain tank daily or after use Internal rust causes tank failures and explosions 13 Do not use the air hose to move your air compressor 14 Do not grind puncture torch or in anyway modify the compressor s tank 15 Disconnect the plug from the power source and drain all air from the tank before making any adjustments changi...

Страница 6: ...RED GAUGE FOR EXTENSION CORDS UL Recommendations 25 ft 50 ft 100 ft 150 ft 13A 12 gauge 10 gauge 8 gauge 6 gauge ELECTRICAL INFORMATION WARNING This tool is for indoor use only Do not expose to rain or use in damp locations GROUNDING INSTRUCTIONS IN THE EVENT OF A MALFUNCTION OR BREAKDOWN grounding provides the path of least resistance for an electric current and reduces the risk of electric shock...

Страница 7: ...UR AIR COMPRESSOR Tank Tank Drain Valve Motor Handle Power Cord Pressure Switch Regulated Pressure Gauge Air Filter Air Pressure Regulator Air Line Outlet Oil Cap Breather Pump Oil Gauge Tank Pressure Gauge 7 ...

Страница 8: ...e compressor to automatically start up and shut down depending on its need for air NOTE make sure this switch is set to OFF before unplugging plug ging in or storing the compressor INSTALLING THE WHEELS Insert bolt M10X1 25X57 into the wheel through the wheel bracket and 10mm flat washer then tighten with M10X1 25 hex nut Repeat for both wheels INSTALLING THE AIR FILTER Remove the plastic plug Ins...

Страница 9: ...ure that this pressure is not higher than the working pressure of any pneumatic tools hooked up to the compressor Using a pressure higher than the rated pressure of an attached tool creates the possibility of damaging or in worse case scenarios bursting said power tool Using a pressure that is too low for a tool can result in misfires and improper functionality 3 2 1 5 4 SHUTTING DOWN THE COMPRESS...

Страница 10: ...When the oil level is below B refill with semi synthetic compressor oil until the level reaches the center of the red circle in the oil gauge Oil should be changed after 200 hours of operation Prepare a container to catch the oil and unscrew the M6 oil drain plug on the pump head The compressor may need to be tipped slightly to let the oil drain completely After the oil has been drained tighten th...

Страница 11: ...sor is too small Check the requirements of the pneumatic tool Make sure the specifications of this compressor meet the requirements Motor won t run 1 Tank pressure is too high 2 Thermal overload protection on the motor has been tripped 3 Power source isn t working 4 Check valve part 11 is stuck open 1 Motor will start automatically once the tank pressure drops 2 Let the motor cool down for a few m...

Страница 12: ...12 EXPLODED VIEW AND PARTS LIST ...

Страница 13: ...15 2202 016 Elbow 3 8 NPT 9 16 1 16 2289 017 Ferrule 3 8 Tubing 2 17 2289 018 Ferrule 1 4 Tubing 2 18 2289 019 Nut Compression 3 8 9 16UNEF 2 19 2289 020 Nut Compression 1 4 7 16UNS 2 20 2287 020 Cooling Fin 3 8 450 1 21 2287 021 Outlet Tube 3 8 L224H 1 22 2287 022 Tube Pressure Relief L26 1 23 2287 023 Rubber Grip Handle 1 24 2202 028 Bolt M10X1 25X55 2 25 2287 025 Bolt Hex Head M8X1 25X25mm 1 26...

Страница 14: ...The prod uct must be shipped in its original container or an equivalent properly packed to withstand the hazards of ship ment The product must be fully insured with a copy of the warranty card and or the proof of purchase enclosed There must also be a description of the problem in order to help our repairs department diagnose and fix the issue Repairs will be made and the product will be returned ...

Страница 15: ......

Страница 16: ...THANKS FOR REMEMBERING ...

Отзывы: