background image

7

Owner’s Manual

WPC-15000 / WPC-15003

Maintenance

FILTER CLEANING 

(See Figures 7 and 8)

There are three 

fi

 lters in the unit. The evaporator 

fi

 lter is located at the front of the unit. The 

condenser 

fi

 lters are located at the side of the unit.

1. loosen up 2 bolts on the front 

fi

 lter guard.

2. Slide 

fi

 lter up and use a vacuum cleaner to remove the dust from the 

fi

 lter.

3.  If the 

fi

 lter is heavily covered with dust and dirt, warm water and mild soap or neutral deter-

gent may be used to wash the 

fi

 lter. Do not use any other chemicals to clean 

fi

 lter, as they will 

likely damage the 

fi

 lter.

4.  Dry the 

fi

 lter in a shaded area before replacing it. Do not operate the unit without the 

fi

 lter 

installed and the 

fi

 lter guard in the closed posi  on.

5. Replace the clean 

fi

 lter and close the 

fi

 lter guard.

6.  To clean the condenser 

fi

 lters, li   up on the side 

fi

 lters from the middle bar slightly and then 

angle the 

fi

 lters outwards from the bo  om and remove.

7.Use the same cleaning procedure as above (3 – 5).

8.  To replace the condenser 

fi

 lter, place the top of the 

fi

 lter in the guide and slide the 

fi

 lter up 

un  l the bo  om of the 

fi

 lter clears the frame. Then push the bo  om of 

fi

 lter into the guide 

and let 

fi

 lter gently fall inside the guide.

NOTE: For e

 ec  ve cooling clean the 

fi

 lter at least every 2 weeks.

–  For your convenience, record the complete model number and product name (located on the 

Product Iden  

fi

 ca  on Plate), the purchase date, purchase loca  on, serial number, and warranty 

period in the table below.

–  Also, a  ach your purchase receipt as proof of purchase to this instruc  on manual for future 

reference.

–  To ensure your product is covered by warranty, the complete faulty product along with your 

original purchase receipt must be provided at the place of purchase.

Do not operate without the 

fi

 lter 

fi

 

Ʃ

 ed.

Do not operate the unit with a damaged cord or plug, a

Ō

 er the unit malfunc-

Ɵ

 ons, or if the unit has been dropped or damaged.

– Loosen up 2 bolts on
   the front filter guard.

– Slide filter up and use
   a vacuum cleaner to remove
   the dust from the filter.

– Remove dust from the filter
   using a vacuum cleaner
   hose aachment. 
– If required wash the filter in
   lukewarm water with a mild
   detergent. Leave to dry in
   a shaded area before
   reinstalling.

Figure 7 – Removing Filters

Figure 8 – Removal of Dust

Содержание americool WPC-15000

Страница 1: ...sual display of the fault is shown Caster wheels are included for easy portability Suitable applica ons include a factory or work place industrial kitchen computer room emergency cooling outdoor event...

Страница 2: ...s inlet and outlet grilles 8 DO NOT use the unit in areas where it will be exposed to rain or water 9 NEVER unplug the unit while it is opera ng Model No Se ng temperature Room cool mode F C Se ng tem...

Страница 3: ...rson must replace it in order to avoid a hazard or shock 19 The filters must be used with the product at all mes When the filters are removed for clean ing always ensure that the unit has been turned...

Страница 4: ...sedinsideofbox withcoolairoutlethose s toinstall thecoolairoutlethose s ontheaircondi onerasshownin Figure5 1 Take out the cord holder from the accessory box 2 Placethecordholderon thebacksideofaircon...

Страница 5: ...r prongs NOTE Make sure the AC outlet is free of dirt dust oil water or any other foreign material WARNINGS REGARDING PROPER LOCATION FOR INSTALLATION Do not use the unit in explosive environments or...

Страница 6: ...m opera on If Alarm oc curs compressor stops System opera on stops when ALARM light is ac vated blinks longer than 3 minutes 7 CURRENT TEMP Displays current room temperature in display in Fahrenheit I...

Страница 7: ...top of the filter in the guide and slide the filter up un l the bo om of the filter clears the frame Then push the bo om of filter into the guide and let filter gently fall inside the guide NOTE For...

Страница 8: ...keep this manual for future reference and keep sales receipt as proof of purchase SELF DIAGNOSTIC CODES See Table 1 The alarm light is ac vated if abnormal opera on occurs and a code is displayed on t...

Страница 9: ...kinked Do not use the air condi oner if ambient temperature is higher than 45 C 113 F Abnormal tempera ture sensor value TH1 Outlet tem perature sensor has a loose or broken connec on Contact a quali...

Страница 10: ...Owner s Manual WPC 15000 WPC 15003 Wiring Diagram Figure 9 Circuit Wiring Diagram WPC 15000 TH1 TH2 TH3 RELAY RELAY TIMER TB N 1 DEALY 20 seconds DRAIN PUMP NO 1 COMP NO 2 COMP L 1 POWER 1P AC 208 23...

Страница 11: ...3 POWER 3P AC 380V 50HZ 3P AC 460V 60HZ DRAIN PUMP R L1 S L2 T L3 C CM PHASE PROTECTOR 380 440V 220V TR MB MC1 OCR1 R S T R E S T R S T R S T R S T MC2 COM Comp Over Load H L OCR2 B NC A NO Wiring Dia...

Страница 12: ...wer cord No cold air flows from the cold air outlet 1 Ambient air cannot be properly cooled if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit i...

Страница 13: ...on vi modifications or alterations to the Products vii use with parts or devices not supplied or approved by AmeriCool viii improper installation or service ix shipping damage to any units or spare pa...

Отзывы: