The removable rechargeable battery used is a Lithium Ion cel!. When supplied the battery may hoId a small
charge, the unit should be run fiat and then charged for sixteen hours before the first use.

5. Unpacking 

 

 

  Assembly 

 

 

  Usage :

5.1. Unpacking:
 Check that the package is complete and that no part is damaged due to the
transport or for other reasons.
A package with the complete system including accessories contains:
1. Blower unit incl. Battery and P R SL Filter and Pre Filter
2. Belt
3. Air hose
4. Air flow indicator
5. Battery charger
6. User Instructions

5.2. Assembly:
Attach the respiratory unit onto the belt: Pass the inner strap through the back of the
blower loops. The pass through the 2 belt loops and then through the buckle.
Fit the battery to the Blower unit.

5.2.1. 

Waist-Belt Adjustment:

Put the belt around your waist with the blower unit to the back and fasten the two ends together. If
the belt is too loose, siide the male adjuster down the belt, towards the female half. If the belt is too
tight, slide the male adjuster away from the female half.
Repeat the above processes until a comlortable and secure lit is achieved. Once the belt lits correctly, secure
any excess belt material using the Velcro sections.

5.2.2. 

Particulate Filter: 

Use only Airkos filters and Pre Filters as supplied by Weltek

It should first be ascertained by consulting an

occupational hygienist or by calling the manufacturers technical help line as ta whether or not the Airkos*
Filter will offer suitable protection from the hazard.
The respiratory power unit is equipped with a high efficiency particle filter  

 

class PRSL and a Pre Filter. As

soon as the warning alarm sounds, the pre fiIler should be exchanged or checked. In very dusty area's this
can be necessary on a frequent basis.
The filters must be regularly checked (see Air Flow Test) and replaced. Make sure that the new filters are
within their expiry date, unused and not evidently damaged . From the hygienic point of view the maximum
working time of

 

a main filter is 180 hours and should not be exceeded. It is prohibited to clean the filters by

any procedure!

5.2.3. Removing the Filter:
Opening the lilter cover: Grip the blower and pull up the cover Irom the right side 

01

the blower.

ATTENTION ! lt is strictly forbidden to use any tools to open the filter cover. To remove the lilter, pull it off the
lilter seal while rotating it. Clean the unit trom dust.

5.2.4. Fitting a new Filter:
Inserting a new filter: Put the lilter back into position using the same rotating motion and gently push until it
lits weil on the body 

of 

the unit.

Closing the filter Cover; simply snap the cover into place. Pay special attention to snap the caver properly
into the blower. Do not attempt to use the blower unit without the cover litted correctlv.

5.2.5.Changing the Pre Filter 
The pre filter is a sleeve which is fitted over the main filter. To remove / replace simply pull off the old filter
and   stretch   the   new   one   into   position.   It's   important   to   ensure   that   the   filter   media   of   the   main   filter   is
completely covered by the pre filter

5.2.6.Attaching the Hose to the Blower Unit:
Align the pins of the Hose Sayonet connector with the slots in the air outlet of the blower. Push the bayonet
connector into the blower until it reaches the bottom of the hole and then twist in a clockwise direction until
the locating pins clips into place.
Fitting the hose to the hoods is the same procedure.

5.2.7.Donning theWelding Helmet:

Содержание Airkos CR-2B01/2013

Страница 1: ...Airkos CR 2B01 2013 Covers Helmets PL 2B01 2013 and GT 2B01 2013...

Страница 2: ...5 1 5 2 1 5 2 2...

Страница 3: ...5 2 3 5 2 5 5 2 7 5 3...

Страница 4: ...6 2 6 3 6 3 2...

Страница 5: ...10...

Страница 6: ...semblyi Usage 6 Before Use 7 Maintenance Cleaning 8 Fault finding 9 Storage and transportation 10 List of Parts 11 Technical data 12 Warranty 1 Introduction Airkos is a respiratory protective system w...

Страница 7: ...ms are for use only by competent trained personnel Filters should not be modified to fit different blower units ATTENTION If any of these conditions are not kept or followed the warranty is automatica...

Страница 8: ...soon as the warning alarm sounds the pre fiIler should be exchanged or checked In very dusty area s this can be necessary on a frequent basis The filters must be regularly checked see Air Flow Test a...

Страница 9: ...orn parts Carefully examine the air hose seals and the face piece There is a good connection between the air hose and the headpiece as well as the blower unit There is sufficient air flow see 6 2 The...

Страница 10: ...not faulty or malfunctioning if so diodes do not work Filters and their clogging That there is not a hole in the air hose Whether the hood seal is not damaged Whether the working time after a full rec...

Страница 11: ...inst solid particles L means the filter proteet against Iiquid particies 12 Warranty The Airkos Blower unit is guaranteed for a period of 12 months from date of purchase against mechanical or electric...

Страница 12: ...Manufactured By ZI DES BATTERSES 01700 BEYNOST FRANCE Tel 33 0 4 37 85 54 27 Fax 33 0 4 78 55 64 68 contact weltekinternational com www weltekinternational com...

Страница 13: ...ernational com CE certifications available from www weltekinternational com Part Number 1 CR 7050 2 CR 7060 3 CR 7020 4 CR 7021 5 CR 7022 6 CR 7023 7 CR 7001 8 CR 7002 9 CR 7010 10 CR 7012 11 CR 7030...

Отзывы: