7.
Maintenance / Cleaning:
The Blower unit, filler housing and head units must ail be regularly cleaned to keep them in good working
order.
For single users, the units can all be cleaned with a cloth moistened with luke warm water and soap.
For multiple users, the units should be disinfected when passed from one user to another.
The Manufacturer recommends that 'Incidur' from Ecolad GmbH
&
Co. OHG is used for disinfecting.
Liquids must not be allowed to enter the workings of the blower unit or get on to the element of the filter.
Parts should be allowed to air dry. Under no circumstances should any solvents or abrasive cleaning agents
be used.The unit must not be dried using hot air or radiant heat.
The unit should continue to provide protection to the designed specification for 2 to 3 years, when maintained
in accordance with these instructions. Prior to each use the user should check that the unit is free from
defects, such as cracks, split filters and hoses, cracked visors and helmet components as appropriate
8.
Fault finding :
If there is a sudden change in air supply while using the Airkos* system, it is necessary to check the
following:
That all parts of the air-supply system are assembled properly.
The battery and its connector.
Whether the charger is not faulty or malfunctioning (if so, diodes do not work).
Filters and their clogging.
That there is not a hole in the air hose.
Whether the hood seal is not damaged.
Whether the working time after a full recharging of the battery has not decreased (if so, it is necessary to
replace the battery).
9.
Storage and Transportation:
When not in use or during transportation the blower and head units should be stored in the
container in which they were provided, or other similar container, such that it is out of direct sunlight,
not in contact with solvents and cannot be damaged by physical contact with hard suriaces/items.
Do not store outside the temperature range of +O°C to +40°C or with humidity or with humidity above
75%RH
10. List of parts
10. List of parts
10. List of parts
10. List of parts
1
Face Seal for PL-2B01/2013
CR7030
1
Face seal for GT-2B01/2013
CR7032
2
Head Gear and Air Duct Assembly
CR7025
3
Hose and Cover Assembly
CR7010
4
Belt
CR7001
5
Euro Charger
CR7022
5
Universal Charger
CR7023
6
Battery
CR7020
7
Blower Unit
CR7082
8
Filter
CR7050
9
Pre Filter
CR7060
11. Technical data:
This powered respirator is light-weight and easy to handle. It is equipped with a replaceable
particulate filter. The system affords reliable protection against particulates and aerosols.
Air flow: 180 to 220 Litres/ min. Minimum flow rate 170 Litres/ min.
Weight with filter: 920 grammes
Type of filter: P R SL
Type of Battery: Replaceable and rechargeable Li-Ion 7.4V/5200 mAh
Содержание Airkos CR-2B01/2013
Страница 1: ...Airkos CR 2B01 2013 Covers Helmets PL 2B01 2013 and GT 2B01 2013...
Страница 2: ...5 1 5 2 1 5 2 2...
Страница 3: ...5 2 3 5 2 5 5 2 7 5 3...
Страница 4: ...6 2 6 3 6 3 2...
Страница 5: ...10...