background image

 

 

Weltech

 

Interna onal

 

Limited

 

manufacture

 

the

 

BW

2050

 

to

 

the

 

highest

 

speci

fi

ca on

 

and

 

our

 

aim

 

is

 

to

 

con nue

 

to

 

improve

 

its

 

opera on

 

and

 

reliability

 

and

 

give

 

our

 

customers

 

a

 

product

 

that

 

suits

 

their

 

requirements.

 

SERVICE.

 

For service and repairs contact your local agent.  

Weltech Interna onal Limited 
10 Bramley Road 
St.Ives 
Cambridgeshire 
PE27 3WS 

Email :    [email protected] 
Tel :        +44 (0) 1480 461611 
Fax :       +44 (0) 1480 301010   

 

Weltech Interna onal Limited 

Содержание BW-2050

Страница 1: ...and will retain all weights even when the ba ery is flat The BW 2050 can store up to 5000 bird weights Weights can be placed into 1 50 separate stores All informa on is stored un l the CLEAR sequence has been completed The maximum weight the unit can weigh is 10kgs 22lbs for the chicken version and 50kgs 110lbs for the turkey weigher BW 2050 Control Panel Printer Computer and USB op onal ports are...

Страница 2: ...hows 0 000 KGS if not press TARE Power off the weigher and a ach the shackle Power on the weigher and press the TARE key The weigher will tare out the shackle weight and show 0 000 KGS This tared weight will stay in the weigher un l another tare is done SETUP OPTIONS To reset the weigher back to Factory se ngs hold the MEMORY STORE bu on and turn on The display will show WELTECH SET UP un l the bu ...

Страница 3: ...is sent to the printer and can be changed using the INC or DEC bu ons Baud rate for serial port BLUETOOTH H SHK OFF Not an available op on PRINTER H SHK OFF This is not used with our printer PRINTER LINEFEED ON Sends line feed to printer after a new line PRINTER DELAY 0 1 SECS This is the delay time from pressing the print data button to the actual print function WEIGHT RANGE Chicken or Turkey To ...

Страница 4: ... LOW LIMIT 0 050 Lower acceptance limit HIDE DISPLAY OFF Hides the weight when ready AUTO ZERO FILTER 6 Drives the display towards zero at low weights Do not alter VOLTAGE FILTER 6 Ba ery voltage filter steepness Do not alter DIVISIONS 1 Where a number of birds are being weighed together the program can be set to divide by the number of birds to give an average DEVIATION METHOD WELTECH Universal s...

Страница 5: ... bu on To clear data already stored in the weigher press CLEAR the display will then ask you to press ENTER a er this the display will then ask you to confirm by pressing SET UP to escape press CLEAR Data will remain in the memory un l cleared The display will then show STORE 1 Ba ery charge indicator Time Select the house the weights are to be stored in by pressing MEMORY STORE press the INC or D...

Страница 6: ...in the USB s ck Press the PRINT DATA key and the display will show WRITING TO USB When the weigher has finished the display will flash up FILE WRITTEN OK and the display will go back to the standard weighing display The USB s ck can now be removed and used on a computer If there is no USB s ck in the weigher when you try to write to the USB the display will show WRITING TO USB followed by NO STICK...

Страница 7: ...ed in the weigher will remain in memory even if the unit automa cally turns off To recharge the ba eries fully leave on charge over night To check the ba ery voltage or charging voltage Hold the SET UP bu on down and turn ON the display will show WELTECH SET UP then DATA STORES press CLEAR and then the INC key If the INC or DEC key is pushed the display will show the date me and ba ery charge By pu...

Страница 8: ...INT DATA Prints data INC DEC Increase se ngs Decrease se ngs CLEAR Clear data stored SET UP Engineers se ngs SET BANDS Set grading bands or target weights FAST SLOW Selects between fast or slow weighing PRINT OPTIONS Set type of printout Sta s cs Histogram Each ENTER Enters data into store command CAL Sets zero tare and calibra on Charging Socket RS232 Output Printer Computer USB STICK Socket if f...

Страница 9: ... CLEAR Clear memory PRINT Print standard reports SETTS Print se ngs report RESET Restart the processor OFF Power down 16 USING THE USB Turn weigher on and open PRINT OPTIONS and make sure WRITE TO USB is on Plug USB s ck into port Shown on page 15 and press PRINT DATA Once the file is wri en FILE WRITTEN OK will appear on the screen the data is now downloaded Remove the USB s ck from the weigher a...

Страница 10: ...ed in water Carrying the unit by the hook may cause damage to the loadcell and stop you from weighing This unit is fi ed with rechargeable ba eries and will last for 3 4 years INDEX Subject Page Introduc on 1 Calibra on 2 Setup Op ons 3 Operator Se ngs 4 Opera ng Instruc ons 9 Printer Output 12 Charging 13 Key Pad 14 PC Opera on 15 Remote Commands 16 Using The USB 17 Safety Considera ons 18 ...

Страница 11: ...ts opera on and reliability and give our customers a product that suits their requirements SERVICE For service and repairs contact your local agent Weltech Interna onal Limited 10 Bramley Road St Ives Cambridgeshire PE27 3WS Email info weltech co uk Tel 44 0 1480 461611 Fax 44 0 1480 301010 Weltech Interna onal Limited ...