CH8 SIP Trunk
SIP Trunk (the physical port is
WAN RJ-45
connector) was used to make call
from GSM line to SIP IP network to remote device, or receive incoming call
from remote device to WellGate M4 via SIP IP Trunk.
WellGate M4 needs to be set up the SIP trunk for VOIP outgoing call from GSM
line and incoming call from SIP Trunk to GSM line. There are up to 4 SIP trunk
can be used for whole system.
Figure 8-0 shows four SIP Trunk major configuration status. You can click each
Trunk to enter details contents and modify your desire parameters.
Figure 8-0 SIP Trunk page
Trunk ID: SIP trunk ID selection. There are 4 SIP Trunks can be
used.
Register Type: This feature is used to connect WellGate M4 with
other SIP devices or SIP Server. Register type has two modes:
Predefine or Register.
Predefine
is used to connect to SIP Server or
IP-PBX directly, however,
Register
is registering to SIP Server or
IP-PBX as a Gateway.
TEL No: The Telephone Number for the SIP account.
Proxy Server: The SIP proxy server or IP-PBX IP address.
Proxy Server port: The SIP proxy server or IP-PBX port.
Outbound Proxy: The SIP outbound proxy server IP address.
Outbound Server Port: The SIP outbound proxy server port.
Export: To back up or copy out these 4 SIP Trunk configurations to
your computer’s hard disk as SIP Trunk File.
Import: To reload setting of SIP Trunk from your computer stored
file.