background image

17

1.  Switch the Body Lifter on with the power 

button (hold the 

multi-function button

 under 

the silicone cover 

on the right side

 of the 

device for about 3 seconds). The 

default 

setting

 of the display shows 

SLIM

 (RF 

programme "Slimming") plus 

ARM

 (body region 

“Arms”) plus L (intensity level “Low”).

2.  First of all, select the body area you want to 

treat. You can choose between 6 body areas: 
ARM (arms), WAI (waist), ABD (abdomen), 
BUT (buttock), HIP (hips), LEG (legs) by 
shortly pressing (1 s) the 

right multi-function 

button

 per body area. The display shows the 

treatment time simultaneously that matches 
optimally with the body area chosen.

3.  Secondly, select the RF programme you would 

like to use to treat the chosen body region 
with. Press the 

multi-function button

 under 

the silicone cover 

on the left side

 of the 

device shortly (1 s) per programme. STRET 
(“Stretching") is the third RF programme.

4.  Thirdly, select the intensity level for the 

programme you have chosen. Press the 

left 

multi-function button

 again shortly (2 s) per 

intensity level. You can choose between 3 
intensity levels: L “low”, M “medium”, H “high”.

5.  Start the treatment by shortly pressing (2 s)  

on the 

right multi-function button

6.  The integrated timer begins to count down. 

7.  You will recognize the programme activation 

through the pulsing squares displayed in 
the intensity and operating status icon in the 
bottom center of the display area.

8.  You can interrupt and re-start the treatment 

programme by pressing the 

right multi-

function button

 shortly (2 s) again.

9.  Switch the Body Lifter off after the treatment by 

pressing the 

right multi-function button

 for 

about 3 seconds.

10. At the end, clean the treatment heads carefully. 

Wipe leftover gel with a damp cloth or sponge. 
Do not use running water to clean the device!

Содержание BYAS

Страница 1: ...DISCOVER BYAS PROFESSIONAL HOME BEAUTY HI TECH USER MANUAL AND PRODUCTION INFORMATION...

Страница 2: ...at the same time as effective as possible The BYAS PERFECTION SYSTEM combines the latest research worldwide in a holistic hybrid concept in which three unique modules interact in a highly effective wa...

Страница 3: ...CONTENTS SHORT OVERVIEW 03 TREATMENT ADVICES 05 RADIOFREQUENCY PROGRAMMES 07 EMS PROGRAMMES 13 BYAS BODY FORMING GEL 19 WARNINGS AND CARE INSTRUCTIONS 21 CONTRAINDICATIONS 22 CONFIRMATION OF CONFORMI...

Страница 4: ...our weekly fitness programme then it s time for you to do so WHAT IS THE BYAS BODY LIFTER The Body Lifter is a part of the BYAS Professional Home Beauty Hi Tech Device series Achieve fantastic body fo...

Страница 5: ...t triglycerides HF EMS High Frequency Electrical Muscle Stimulation A high frequent pulse activation strengthens the body muscles in a highly effective way and offers simultaneously highest compatibil...

Страница 6: ...ly to select approx 1 sec arms ARM waist WAI abdomen ABD buttocks BUT hip HIP legs LEG Choose treatment programme Press the button on the left side of the device B each time shortly approx 1 sec Defau...

Страница 7: ...ny pressure onto the skin during a treatment Make sure there is always enough gel under the electrodes Interrupt Continue Press button A approx 2 sec Security System ATSEC PES Pulsating beep tones fro...

Страница 8: ...status Display of the intensity level and the current operating status active standby 2 Battery symbol Display of the current charge state 3 Multi function button Select RF EMS programmes and program...

Страница 9: ...output regulation when the maximum temperature is or is not exceeded Automatic temperature safety control ATSEC 7 PES Integrated acoustic guidance system that leads the user individually through the R...

Страница 10: ...eatment heads have to contact the skin evenly Hold the Body Lifter in such a way that all four treatment heads contact the skin evenly This important because otherwise the depth effect of the Body Lif...

Страница 11: ...e to fall As soon as the skin temperature starts declining the continuous acoustic signal becomes pulsating again When the measured warmth in the skin reaches 42 C again the Body Lifter s output is co...

Страница 12: ...reas of the body move step by step Carry out the treatments successively each with palm sized parts you have previously applied gel on When carrying out a treatment always ensure that the four treatme...

Страница 13: ...t side of the device shortly 1 s per programme SLIM Slimming is the first RF programme 4 Thirdly select the intensity level for the programme you have chosen Press the left multi function button again...

Страница 14: ...of the Body Lifter touch the skin evenly to achieve optimal results with the Body Lifter Do not apply any pressure onto the skin during the treatment The Body Lifter s own weight offers enough pressu...

Страница 15: ...ft side of the device shortly 1 s per programme SHAPE Shaping is the third RF programme 4 Thirdly select the intensity level for the programme you have chosen Press the left multi function button agai...

Страница 16: ...t to treat larger areas of the body move step by step Carry out the treatments successively each with palm sized parts you have previously applied gel on When carrying out a treatment always ensure th...

Страница 17: ...t side of the device shortly 1 s per programme STRET Stretching is the third RF programme 4 Thirdly select the intensity level for the programme you have chosen Press the left multi function button ag...

Страница 18: ...ng that is less intense Apply the BYAS Body Firming Gel with the active body shaping LIPOrelease special ingredient complex generously to the area to be treated If you want to treat larger areas of th...

Страница 19: ...device shortly 1 s per programme SMTH Smoothing is the first EMS programme after the three RF programmes 4 Thirdly select the intensity level for the programme you have chosen Press the left multi fun...

Страница 20: ...uscles Apply the BYAS Body Firming Gel with the active body shaping LIPOrelease special ingredient complex generously to the area to be treated If you want to treat larger areas of the body move step...

Страница 21: ...device shortly 1 s per programme FIRM Firming is the second EMS programme after the three RF programmes 4 Thirdly select the intensity level for the programme you have chosen Press the left multi func...

Страница 22: ...the muscles Apply the BYAS Body Firming Gel with the active body shaping LIPOrelease special ingredient complex generously to the area to be treated If you want to treat larger areas of the body move...

Страница 23: ...device shortly 1 s per programme LIFT Lifting is the third EMS programme after the three RF programmes 4 Thirdly select the intensity level for the programme you have chosen Press the left multi func...

Страница 24: ...effect on the breakdown of fats Lipolysis Clinical studies in the field show a detectable anti cellulite effect after just two weeks DOUBLE EFFECT LIPORELEASE SPECIAL COMPLEX Consists of a highly inno...

Страница 25: ...There they act as a catalyst to enhance the effects of the Body Lifter with their special fat formation restriction and fat breakdown stimulation properties APPLICATION INSTRUCTIONS All skin types Fo...

Страница 26: ...is always enough gel under the treatment heads to avoid possible skin irritations Increase the amount of gel used if necessary particularly when you have a strong sensation of warmth on the skin duri...

Страница 27: ...r rashes By persons who have had surgery laser treatment or deep action chemical peeling in the treatment area within the past 3 months or the consequences of such interventions have not yet completel...

Страница 28: ...NFORMITY We confirm that the BYAS Body Lifter complies with the guidelines of the EU regulation 2011 65 EU Restriction of hazardous substances in electrical and electronic equipment 2014 30 EU electro...

Отзывы: