![Wells WV-4H Series Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/wells/wv-4h-series/wv-4h-series_owners-manual_955586005.webp)
M504 p/n 2M-303903 Owners Manual WV
-4H V
entless Hotplate Cooktop
3
FEATURES & OPERATING CONTROLS (continued)
VENTILATOR SECTION
ITEM
DESCRIPTION
COMMENT
a6. FIRE SUPPRESSION AGENT TANK (1.5 gal.)
Container for Ansulex™ Low-pH liquid fire suppression liquid.
8
ADJUSTABLE (FRONT) LEG
Allows the unit to be leveled.
9
RIGID (REAR) CASTER
Allows the unit to be easily positioned by lifting the front of the unit
slightly.
a10. MANUAL PULL STATION
Provides a means of manual activation of the fire suppression system.
PULL ONLY IN CASE OF FIRE!
a11. FUSIBLE LINKS
Automatically activates fire suppression system in the event of fire on
the cooktop.
12
LOWER REAR ACCESS PANEL
Allows access to Ansul® fire suppression agent tank (a6) and controls
also access to main power contactor (41).
a15. DISCHARGE NOZZLE
Fire suppression media discharges here (2 places).
16
GREASE BAFFLE
Extracts and drains most grease and moisture from the air flow.
18
PRE-FILTER ASSEMBLY
Comprises the PRE-FILTER FRAME and a replaceable PRE-FILTER.
Stops larger particles of grease from reaching the FILTER PACK for
reduced maintenance costs.
19
HEPA/CHARCOAL FILTER PACK
Stops most grease and smoke particles. Also assists in some cooking
odor removal.
22
GREASE CUP
Collects grease/moisture drained from grease trough (23).
23
GREASE TROUGH
Directs grease/moisture removed by grease baffle to grease cup.
28
VENTILATOR EXHAUST DUCT
Exit point for ventilator airflow - on top left rear of unit.
DO NOT
BLOCK
a31. STATUS INDICATOR
Displays status of fire suppression system (
COCKED - FIRED
) If
FIRED
, a buzzer will sound continuously.
38
POWER CORD
6’ cord and cap. Plug for NEMA 15-60R (receptacle by user).
40
WARMER RELAY
Provides power to roll warmer section. Energized at all times except
during fire safety shut-down.
41
POWER CONTACTOR
Energizes cooktop only while ventilator section is sensed as
operational.
42
BUILDING FIRE ALARM RELAY
Reports fire alarm condition to building fire management system.
43
GROUND LUG
Ground wire of power cord connects here.
44
INTERLOCK TERMINAL
Provides connection for shut-down control by building fire
management system.
56
VENTILATOR FAN
Provides air movement for ventilation.
70
COOLING FAN
Provides cooling for cooktop controls.
Содержание WV-4H Series
Страница 24: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 22...
Страница 25: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 23...
Страница 26: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 24...
Страница 27: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 25...
Страница 29: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 27 PARTS BREAKDOWN for ANSUL COMPONENTS...
Страница 34: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 32 EXPLODED VIEW PARTS LIST COOKTOP COMPONENTS...
Страница 38: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 36 WIRING DIAGRAM HOOD SECTION...
Страница 39: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 37 WIRING DIAGRAM HOTPLATE COOKTOP SECTION...
Страница 41: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 39 NOTES...
Страница 42: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 40 NOTES...
Страница 44: ...WELLS MANUFACTURING 265 Hobson Street Smithville Tennessee 37166 telephone 800 264 7827 www wells mfg com...