background image

WELLS 

MANUFACTURING 

265 Hobson Street, Smithville, Tennessee 37166 

telephone: 314-678-6314

fax: 314-781-2714

www.wells

-mfg

.com

IMPORTANT:  DO NOT DISCARD THIS MANUAL 

This manual is considered to be part of the appliance and is to be given to the OWNER or 

MANAGER of the restaurant, or to the person responsible for TRAINING the operators of 

this appliance.  Additional manuals are available from your WELLS DEALER. 

THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR 

INSTALLING THIS APPLIANCE.

  Contact your WELLS DEALER if you have any 

questions concerning installation, operation or maintenance of this equipment. 

OPERATIONS MANUAL 

DROP-IN REFRIGERATED  

COLD PANS, 4-THIRDS, NSF7          

RCP-7143, RCP-7243, 

   RCP-7343, RCP-7443, 

  RCP-7543, RCP-7643. 

DROP-IN REFRIGERATED 

COLD PANS, 4-THIRDS, NSF2 

RCP-143, RCP-243, 

   RCP-343, RCP-443, 

  RCP-543, RCP-643. 

 INCLUDES INSTALLATION, USE,  

CARE, SERVICE AND DIAGRAMS. 

403 

2M-

Z16053

04/18

Model RCP-7443 

Содержание RCP-143

Страница 1: ...onal manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WELLS DEALER if you have any questions concerni...

Страница 2: ...ult of normal use within the time period and limitations defined in this warranty will at Wells discretion have the parts replaced or repaired by Wells or a Wells authorized service agency THIS WARRAN...

Страница 3: ...mance and a long economical service life This manual contains the information needed to properly install this appliance and to use and care for the appliance in a manner which will ensure its optimum...

Страница 4: ...LS 2 NOTE This is a general arrangement drawing of an RCP 7243 not to scale All other units are similar Ac tual component positions may vary between units M403 p n 2M Z16053 Owners Manual Drop In Refr...

Страница 5: ...or steam jet The technical content of this manual including any wiring diagrams schematics parts breakdown illustrations and or adjustment procedures is intended for use by qualified technical personn...

Страница 6: ...when the pan rails are installed in the lowest position otherwise it meets NSF Standard 2 The RCP 143 thru RCP 643 meet the standards set by NSF 2 and should not be used to hold potentially hazardous...

Страница 7: ...he appliance Carefully account for all components and accessories before discarding packing materials Store all accessories in a convenient place for later use RCP units must remain upright at all tim...

Страница 8: ...its IMPORTANT Damage due to being connected to the wrong voltage or phase is NOT covered by warranty INSTALLATION ELECTRICAL INSTALLATION 1 Refer to the nameplate Verify the electrical service power V...

Страница 9: ...es Consult local codes for approved drain configurations IMPORTANT DO NOT allow the sink drain spud to turn during installation Hold the spud with an appropriate cross guard style spud wrench or caref...

Страница 10: ...1 Turn POWER SWITCH located on condensing unit ON Allow unit to run for approximately 30 minutes to reach operating temperature 2 Add necessary adapter bars or adapter plates Adapter bars provided wi...

Страница 11: ...interior of tank using a clean cloth or sponge and mild detergent 2 Use a plastic scouring pad to remove any mineral deposits 3 Rinse tank thoroughly with a vinegar and water solution to neutralize al...

Страница 12: ...card all lint and debris gathered from this operation IMPORTANT The fins of the condenser coil are delicate and easily damaged Use care to brush only in a vertical motion to avoid damaging the coil fi...

Страница 13: ...high quality stainless steel As long as the stainless steel surface is intact the equipment will not rust or corrode Recommendation A water softening device or a cartridge type filtration device may b...

Страница 14: ...Press either up arrow or down arrow to toggle between F and C designation 2 Press SET again to access the setpoint The LCD will display the current setpoint and the S1 annunciator will blink off and...

Страница 15: ...efrigeration personnel only Unauthorized adjustment of the differential settings will void the warranty Press either up arrow to increase the differential or down arrow to decrease the differential to...

Страница 16: ...14 TROUBLESHOOTING M403 p n 2M Z16053 Owners Manual Drop In Refrigerated Cold Pans 4 3rds...

Страница 17: ...OR WIRING COMPARTMENT ON OFF SWITCH GREEN BLACK BLACK GREEN WHITE OVERLOAD WIRING SCHEMATIC MODELS RCP 143 thru 643 115VAC SINGLE PHASE 60 HZ COLD PAN WITH REFRIGERATION COILS FILTER DRYER LIQUID LINE...

Страница 18: ...M403 p n 2M Z16053 Owners Manual Drop In Refrigerated Cold Pans 4 3rds 16 NOTES...

Страница 19: ...__________ ADDRESS ___________________________ STATE ______ ZIP__________ TELEPHONE NUMBER _____ _____ _________ EQUIPMENT MODEL NO _______________ EQUIPMENT SERIAL NO _______________ VOLTAGE check on...

Страница 20: ...WELLS MANUFACTURING 265 Hobson Street Smithville Tennessee 37166 telephone 314 678 6314 fax 314 781 2714 www wells mfg com...

Отзывы: