M O D - 3 0 0 T D M   E L E CT R I C A L   S P E C I F I C AT I O N S :

    MODELS     VOLTS WATTS  AMPS PER LINE 3 PHASE 

AMPS 

POWER

                                       

 

SINGLE PHASE  SUPPLY CORD

 

L1         L2 

L3

 MOD-300TDM/AF   208       3720           10.3         10.3         10.3 

17.9 

NONE

 MOD-300TDM/AF   240       4950           11.9         11.9         11.9 

20.6 

NONE

NOTE: Specifications are subject to change without notice. See installation instructions prior to installing the unit. 

This document is not for installation purposes. 

(44)

1 3/4

(356)

14

(197)

7 3/4

(248)

9 3/4

(159)

6 1/4

(889)

35

(1105)

43 1/2

(600)

23 5/8

(57)

2 1/4

CONNECTION

WATER LINE

EXTERNAL NPT

1/4 INCH

MANIFOLD EACH END

INTERNAL NPT

1 INCH

TYP

M O D E L

M O D - 3 0 0 T D M

WA R M E R   W I T H   A U TO   WAT E R   F I L L

D I M E N S I O N S :

INCH

(MM)

W

E L L S

  M

A N U F A C T U R I N G

MINIMUM CLEARANCE REQUIRED FROM 

UNIT TO THE NEAREST SURFACE 

  BACK 

SIDE 

BOTTOM 

FRONT

 

6 3/4 

4 1/8

  (25) 

(25) 

(171) 

(105)

E6070

STD.4

R

E6070

R

LISTED

R

(44)

1 3/4

(356)

14

(197)

7 3/4

(248)

9 3/4

(159)

6 1/4

(457)

18

(749)

29 1/2

(600)

23 5/8

(57)

2 1/4

MANIFOLD EACH END

INTERNAL NPT

1 INCH

CONNECTION

WATER LINE

EXTERNAL NPT

1/4 INCH

M O D E L

M O D - 2 0 0 T D M

WA R M E R   W I T H   A U TO   WAT E R   F I L L

D I M E N S I O N S :

INCH

(MM)

W

E L L S

  M

A N U F A C T U R I N G

M O D - 2 0 0 T D M   E L E CT R I C A L   S P E C I F I C AT I O N S :

    MODELS     VOLTS WATTS  AMPS PER LINE 3 PHASE 

AMPS 

POWER

                                       

 

SINGLE PHASE  SUPPLY CORD

 

L1         L2 

L3

 MOD-200TDM/AF   208       2480            6.0          10.3          6.0 

11.9 

NONE

 MOD-200TDM/AF   240       3300            6.9          11.9          6.9 

13.8 

NONE

NOTE: Specifications are subject to change without notice. See installation instructions prior to installing the unit. 

This document is not for installation purposes. 

E6070

STD.4

R

E6070

R

LISTED

R

MINIMUM CLEARANCE REQUIRED FROM 

UNIT TO THE NEAREST SURFACE 

  BACK 

SIDE 

BOTTOM 

FRONT

 

6 3/4 

4 1/8

  (25) 

(25) 

(171) 

(105)

(187)

7 3/8

(44)

1 3/4

(248)

9 3/4

(159)

6 1/4

(356)

14

(375)

14 3/4

(597)

23 1/2

(57)

2 1/4

LINE CONNECTION

NPT WATER

EXTERNAL

1/4 INCH

INTERNAL NPT

1/2 INCH

M O D E L

M O D - 10 0 T D

WA R M E R   W I T H   A U TO   WAT E R   F I L L

D I M E N S I O N S :

INCH

(MM)

W

E L L S

  M

A N U F A C T U R I N G

MINIMUM CLEARANCE REQUIRED FROM 

UNIT TO THE NEAREST SURFACE 

  BACK 

SIDE 

BOTTOM 

FRONT

 

6 3/4 

4 1/8

  (25) 

(25) 

(171) 

(105)

M O D - 10 0 T D   E L E CT R I C A L   S P E C I F I C AT I O N S :

   MOD-100TD/AF        208              1240                 6.0              SINGLE                         NONE
   MOD-100TD/AF        240              1650                 6.9              SINGLE                         NONE

  MODELS            VOLTS         WATTS 

AMPS 

PHASE 

POWER SUPPLY CORD 

NOTE: Specifications are subject to change without notice. See installation instructions prior to installing the unit. 

This document is not for installation purposes. 

E6070

STD.4

R

E6070

R

LISTED

R

02/02  •  REV(-)  •  PART NO. 303438

02/02  •  REV(-)  •  PART NO. 303438

02/02  •  REV(-)  •  PART NO. 303438