ELECTRICAL INSTALLATION

 

 

IMPORTANT:  

Appliance must be installed by a licensed electrician in 

accordance with all applicable codes and ordinances. 
 
Refer to the product nameplate.  Verify the electrical service  power.  
Voltage and phase must match the nameplate specifications.  Wiring 
the warmer to the wrong voltage can severely damage the unit or 
cause noticeably decreased performance.   
 
Available electrical service amperage must meet or exceed those          
specifications listed on the specification sheet provided with the        
appliance. 
 
The ground lug of the control unit must be connected to a suitable 
building ground.   Ground connection will be marked “GND” or ”       " . 
 

NOTE: 

 Wire gauge, insulation type and temperature rating , as well as 

type, size and construction of conduit, must meet or exceed applicable 
specifications of local codes and of the National Electrical Code. 
 
 
 
 
 
 
 

PLUMBING INSTALLATION 

 

IMPORTANT: 

 All plumbing installations must be performed by a    

qualified plumber. 
 
This appliance is equipped with a DRAIN LINE that must be connected 
to a suitable building drain.  A drain valve (provided by plumbing       
installer) must be installed for each unit.  Drain valve operating handle 
must be readily accessible by the operator.   
 

NOTE:  

Some jurisdictions may require an approved air gap device in 

the drain.  It is the responsibility of the plumbing installer to determine 
such requirement, to provide and properly install the required device. 
 
This appliance is equipped with autofill to maintain water level in the 
warmer pan.  Water supply connection is 1/4” NPT.  Water supply   
must be connected to a COLD WATER line only.  Maximum supply  
line  water pressure is 120 p.s.i. 
 

NOTE:  

This appliance incorporates an internal backflow preventer   

between  the control unit and the warmer pan.  However, Some         
jurisdictions may require additional back-flow prevention devices in    
the water supply line.  It is the responsibility of the plumbing installer         
to determine such requirement, to provide and properly install the      
required device. 
 

 

CAUTION: 

SHOCK  HAZARD 

 

The ground lug of this         
appliance must be connected 
to a suitable building ground. 
 

IMPORTANT: 

Contact a licensed electrician 
to install and connect         
electrical power to the         
appliance. 

 

IMPORTANT: 

Damage due to being 
connected to the wrong     
voltage or phase is NOT    
covered by warranty. 

 

IMPORTANT:

  Electrical      

installation other than as 
specified on the specification 
sheet will void the UL  listing, 
and may void the warranty.  
 
 
 

NOTE:  

Plumbing connections 

must be made in compliance 
with all Federal, State and  
Local Plumbing Codes and 
Ordinances.

 

INSTALLATION (continued) 

024 

 306391

  

 OpM

anual 

for

 Retherma

liz

er HS

W

-6DAF  

Содержание HSW6DAF

Страница 1: ...person responsible for TRAINING OPERATORS of this appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APP...

Страница 2: ...damage is noted on the freight bill or express receipt and that the note of loss or damage is signed by the delivery person 2 FILE CLAIM FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3...

Страница 3: ...appliance Proper installation professional operation and consistent maintenance of this equipment will ensure that it gives you the very best performance and a long economical service life This manual...

Страница 4: ...l for Rethermalizer HSW 6DAF W ELLS PERFORATED BASE PLATE WATER FILL SPOUT WATER LEVEL SENSOR HEATING ELEMENT TEMPERATURE SENSING BULB WELLSLOKS BACK FLOW PREVENTER WATER FILL TUBE HEATING INDICATOR T...

Страница 5: ...instructions must be read and understood by all persons using or installing this appliance Cleanliness of this appliance is essential to good sanitation Read and follow all included cleaning instruct...

Страница 6: ...iance before starting any installation Read and understand all labels and diagrams attached to the appliance Carefully account for all components and accessories before discarding packing materials St...

Страница 7: ...TE Some jurisdictions may require an approved air gap device in the drain It is the responsibility of the plumbing installer to determine such requirement to provide and properly install the required...

Страница 8: ...o the pan This will cause condensation on the inside of the shrouds Damage caused by condensation is NOT covered by warranty DO NOT use metal implements steel wool or caustic or abrasive cleansers to...

Страница 9: ...temperature sensing probe to avoid damaging the capillary tube 3 Rinse rethermalizer thoroughly with a vinegar and water solution to neutralize all detergent cleanser residue Rinse with clear water 4...

Страница 10: ...vers accumulated scale 2 Heat water to maximum temperature 190 F or higher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner Turn heat control O...

Страница 11: ...el probe with Wells Lime Scale Cleaner Internal damage Contact your Authorized Wells Service Agency for repairs Rethermalizer trips circuit breaker Tank leaking or other internal damage Contact your A...

Страница 12: ...06391 OpManual for Rethermalizer HSW 6DAF Model HSW6DAF PASTA RETHERMALIZER CHILI S PL024 IL1763 Rev A 5 6 09 1 2 3 4 5 6 8 9 10 11 24 22 21 20 18 23 17 16 14 15 19 13 12 7 THERMOBULB ref INSULATION n...

Страница 13: ...6X 2 FTG FLEX CON 90 X 1 2 MOD 10 2I Z12311 2 GASKET FIBER WASHER 11 2K 48198 1 ELBOW 3 8 X 90 DEG BRASS 12 2K 48197 1 NIPPLE 3 8 NPT X 2 BRASS 13 2V 47650 1 VALVE ANTISYPHON 3 8 14 2T 40509 1 THERMO...

Страница 14: ......

Страница 15: ...__________ EQUIPMENT SERIAL NO _______________ VOLTAGE check one 208 240 PARTS SERVICE 13 DESCRIPTION PART NO none available at this time IMPORTANT Use only factory authorized service parts For factor...

Страница 16: ...Created for by WELLS BLOOMFIELD LLC 10 Sunnen Dr St Louis MO 63143 telephone 800 807 8054 fax 314 781 2714 www wells mfg com...

Отзывы: