3
Congratulations on your new Welldana® Machine Unit.
Please read this manual carefully before installing and operating the unit.
On receipt of the unit, please check for transport damage immediately.
Never lift the Machine unit by the pipes or other components. Always lift it by the grid.
This manual is mainly concerned with the Machine unit, although the spa tub will also be mentioned.
For further information on controls, filter, etc, see the accompanying manuals.
Standards.
Welldana® Machine Units comply with current rules and standards on safety.
The product complies with: EN 292-1, EN 294, EN 349, EN 60204-1, EN 50081-2
EN 60 335-2-41, EN 50582-2, EN 55014, MC: EN 50082-1. IP X4.
(Electric heater and 3-function control: EN 60335-2-60: 2000)
The product is
CE
marked.
Welldana® Machine Unit incorporates:
1-pcs. 36-202050
Filter pump
2-pcs. 41-700069
Cartridge filters.
1-pcs. 34-110409
Electric heater
1-pcs. 30-001394
Chlorinator
1-pcs. 36-202113
Hydro-jet pump
1-pcs. 34-015040
Tub control panel
1-pcs. 64-112031-1 3-function control
1-pcs. 64-350150
Transformer
1-pcs. 34-140312
Contactor for electric heater
2-pcs. 64-108225
Level sensor
1-pcs. 66-112075
Regenerative fan
1-pcs. 34-190120
Pressure switch
1-pcs. 34-015041
Remote control unit for
temperature regulation and digital temperature display.
1-pcs. assembly steel grid 600•800 mm
Electrical data.
Power cable 1
4 G 1,5 mm² PKAJ cable; 2 • 230 N + earth.
Power cable 2
4 G 1,5mm² PKAJ cable; 3 • 400 + earth. (electric heater)
Total wattage
12 kW (including 9 kW electric heater)
Voltage
3 • 400 V AC 50-60 Hz
Fuse group
16 A 3-phase group switch (2-pcs)
Filter data.
Filter
6,9 m². Cartridge filter
Filter flow
Max 21 m³/hour.
Filter part.
Spare part cartridge, type 48-709068.
Pump data, etc
.
Filter pump
0.55 kW; 230 V; IP 54; 3,5 A; nominal 13,5 m³ at 8 m
Hydro-jet pump
1.10 kW; 230 V; IP 54; 7.0 A; nominal 23 m³ at 8 m
Regenerative fan
0.75 kW; 230 V; IP 54; 5.8 A
Transformer - lighting
230/12 V AC; 60 VA IP 25
Kontakterboks.
3-poled; coil voltage (A1-A2) 230 V; load 20 A AC3
Klorinator.
Inline with controls; uses slowly dissolving chlorine tablets
Conversion time.
The machine unit is suitable for use with the following spa tubs or similar.
The quantity of water in the spa tub should not exceed 1100 litres.
Conversion time for 1100 litre spa to above machine unit = 0.12 hours.
26-221840 Octave. 26-222040
Classic. 26-221800 Victoria.
26-221370 Catalina. 26-221855 Janette.