5. Operation of the AVR 
 
a. Connect the Electrical Appliances to Regulator 

• Make sure all appliances are turned "OFF", and put power switch of AVR to “OFF” position. 
• For model from 500VA to 2000VA, plug the AC mains cord of the appliances into the output socket of AVR, 
ensuring that the total starting power needed does not exceed the rated maximum output power of the AVR.

 

 

b. Connect Regulator to Electrical Mains 
• 

For model from 500VA to 2000VA, just plug the AC mains cord to wall mains socket.  

 

c. Switch on the regulator,  Switch the power "ON" 

• Put the power switch to "ON" position, the yellow LED will illuminate and blink . At the same time, the digital 
display will show the elapsing delay time. Generally delay time is set at 6~10 seconds. 
• Then the yellow LED lights off and the green will illuminate. 
• The digital display will show output voltage supplying to appliances connected to the regulator. 
• Switch "ON" the appliances one by one. 

  
In Case of Power Failure: 

• Switch "OFF" the regulator and all the appliances. 
• Repeat above steps when power is restored. 
  

d. Display of Input Voltage and Output Voltage                                      

•The output voltage will show in the display after switch it on. 
•By pressing the “Input/Output Voltage Selective Button”, the input voltage will be indicated in the display and 
flash. 
•Press the “Input/Output Voltage Selective Button” again to show the output voltage.

 

 

e. LED Operation 

• When the Green LED is "ON", it indicates Power ON and also that the input voltage and output voltage is 
normal, the AVR is working. 
• When the Yellow LED is “ON” and flash, it indicates that the regulator is in a delay status, the output will be 
delayed. 
• When the Red LED is "ON" and flash, it indicates the regulator is in a protection status.  
 

f. Delay Operation 

• This model is designed with a delay feature to protect appliances especially the appliances with 
compressors(like air-conditioner, fridge, motor, pump,and etc).  which should not be switched on immediately 
after being switched off. 
• The delay time is generally set at 6/180 seconds selectable. 

Select delay or undelay before switch on the 

AVR. 

• Press down the delay button, then you select the delay, the delay time will be 180 seconds. After switch on the 
AVR, wait for 180 seconds, then the AVR delivers output; Press up the delay, it means undelay, under "undelay" 
status, the delay time is 6 seconds. 
 

 

 If you connect the appliances with compressors, we suggest that you select "delay" before 
switch on the AVR. 

 

 
• The delay time will show in the display after switch on the AVR. When delay time has elapsed, delay LED will 
switch "OFF" and display will indicate the AC output voltage. 
 

 

Содержание AVR-REL-500-WL

Страница 1: ...tant Safety Instructions 1 2 Specifications 2 3 Before Installation 2 a Contents b Visual observation 4 Introduction to the Regulator 3 a Front of the Regulator b Rear of the Regulator 5 Operation of the AVR 4 a Connect the Electrical Appliances to Regulator b Connect Regulator to Electrical Mains c Switch on the regulator d Display of Input Voltage and Output Voltage e LED Operation f Delay Opera...

Страница 2: ...circuit makes sure you carefully read all the instructions and warnings in the Installation section of this manual Don t drop any foreign materials like clips nails etc into the equip ment In emergencies damage to the cabinet front panel or mains connections splashing of liquid dropping of any foreign materials into the equipment switch off the AVR pull out the plug and inform the authorized servi...

Страница 3: ...0 Non condensing Noise 56dB full load distance at 1 meter Delay Time 6 180 seconds selectable Protection Output Low Voltage Output High Voltage High Temperature Short Circuit Certification CE EMC LVD IP Class IP20 Protection class I Remarks We reserve the right to change specifications or discontinue models without notice 3 Before Installation Each AVR was tested 100 before shipment check if the A...

Страница 4: ... Output Voltage Input Voltage Green LED Yellow LED Red LED Delay Button On Off b Rear of the Regulator 500 1000VA model 1500 2000VA model Fuse Model AVR REL 500VA WL Power Capacity 500VA 300W Rated Output Voltage 220V Output Voltage Precision 8 Input Voltage Range 140Vac 260Vac Input Voltage Frequency 50Hz 60Hz Fuse AC Input Cable Output Socket Output Input Fuse Model AVR REL 1500VA WL Power Capac...

Страница 5: ...on By pressing the Input Output Voltage Selective Button the input voltage will be indicated in the display and flash Press the Input Output Voltage Selective Button again to show the output voltage e LED Operation When the Green LED is ON it indicates Power ON and also that the input voltage and output voltage is normal the AVR is working When the Yellow LED is ON and flash it indicates that the ...

Страница 6: ... is higher than the normal range If the output voltage is over the normal range the output power supply will cut OFF automatically and the display will show H At the same time the Red LED lights up Once the input city power returns to normal range the AVR will restore the output j Low Output Voltage Protection When the output voltage is below the normal range the output will be cut OFF automatical...

Страница 7: ...her This AVR is designed and made by strict standards and quality control system for common use but if apply to purposes may cause any dangerous to human or other lives include but not limited to the following case please refer to our company a Apply to traffic system b Apply to medical purpose c Apply to nuclear power system d Apply to aviation and aerospace e Apply to all kinds of safety devices...

Отзывы: