background image

USER’S MANUAL 

 

AUTOMATIC VOLTAGE REGULATOR 

Model: AVR-REL-500/1000/1500/2000VA-WL 

 

 

 
 
 
 
4. Introduction to the Regulator 

Familiarize yourself with the various features and facilities by studying the two diagrams below to obtain 
maximum benefit from the regulator. 

 
a. Front of the Regulator 
                    
                                  500/1000/1500/2000VA model 

AVR-REL-500VA-WL

Automatic Voltage Regulator

Power Switch

Input/Output Voltage S elective B utton

I/O

Output Voltage / 
Input Voltage

Green LED

Yellow LED
Red LED

Delay Button

On

Off

 

 
                                  
b. Rear of the Regulator 
  
                                 

 500/1000VA  model                                                           1500/2000VA model

  

 

Fuse

Model: AVR-REL-500VA-WL

Power Capacity: 500VA / 300W
Rated Output Voltage: 220V

Output Voltage Precision: ±8%

Input Voltage Range: 140Vac~260Vac
Input Voltage Frequency: 50Hz/60Hz

Fuse

AC Input Cable

Output 
Socket

Output

Input

 

 
 
 
 
 

 

Fuse

Model: AVR-REL-1500VA-WL

Power Capacity: 1500VA / 900W
Rated Output Voltage: 220V

Output Voltage Precision: ±8%

Input Voltage Range: 140Vac~260Vac
Input Voltage Frequency: 50Hz/60Hz

Fuse

AC Input Cable

Output 
Socket

Output
Socket

Output

Output

Input

 

 

Содержание AVR-REL-500-WL

Страница 1: ...tant Safety Instructions 1 2 Specifications 2 3 Before Installation 2 a Contents b Visual observation 4 Introduction to the Regulator 3 a Front of the Regulator b Rear of the Regulator 5 Operation of the AVR 4 a Connect the Electrical Appliances to Regulator b Connect Regulator to Electrical Mains c Switch on the regulator d Display of Input Voltage and Output Voltage e LED Operation f Delay Opera...

Страница 2: ...circuit makes sure you carefully read all the instructions and warnings in the Installation section of this manual Don t drop any foreign materials like clips nails etc into the equip ment In emergencies damage to the cabinet front panel or mains connections splashing of liquid dropping of any foreign materials into the equipment switch off the AVR pull out the plug and inform the authorized servi...

Страница 3: ...0 Non condensing Noise 56dB full load distance at 1 meter Delay Time 6 180 seconds selectable Protection Output Low Voltage Output High Voltage High Temperature Short Circuit Certification CE EMC LVD IP Class IP20 Protection class I Remarks We reserve the right to change specifications or discontinue models without notice 3 Before Installation Each AVR was tested 100 before shipment check if the A...

Страница 4: ... Output Voltage Input Voltage Green LED Yellow LED Red LED Delay Button On Off b Rear of the Regulator 500 1000VA model 1500 2000VA model Fuse Model AVR REL 500VA WL Power Capacity 500VA 300W Rated Output Voltage 220V Output Voltage Precision 8 Input Voltage Range 140Vac 260Vac Input Voltage Frequency 50Hz 60Hz Fuse AC Input Cable Output Socket Output Input Fuse Model AVR REL 1500VA WL Power Capac...

Страница 5: ...on By pressing the Input Output Voltage Selective Button the input voltage will be indicated in the display and flash Press the Input Output Voltage Selective Button again to show the output voltage e LED Operation When the Green LED is ON it indicates Power ON and also that the input voltage and output voltage is normal the AVR is working When the Yellow LED is ON and flash it indicates that the ...

Страница 6: ... is higher than the normal range If the output voltage is over the normal range the output power supply will cut OFF automatically and the display will show H At the same time the Red LED lights up Once the input city power returns to normal range the AVR will restore the output j Low Output Voltage Protection When the output voltage is below the normal range the output will be cut OFF automatical...

Страница 7: ...her This AVR is designed and made by strict standards and quality control system for common use but if apply to purposes may cause any dangerous to human or other lives include but not limited to the following case please refer to our company a Apply to traffic system b Apply to medical purpose c Apply to nuclear power system d Apply to aviation and aerospace e Apply to all kinds of safety devices...

Отзывы: