2.1 Before You Begin
After unpacking the unit, check the equipment for compliance and any damage that may have occurred during shipment.
Immediately contact a Welker representative if you received damaged equipment.
When sealing fittings with PTFE tape, refer to the proper sealing instructions for the brand used.
All electrical connections must meet local and national electric codes, and excessive weight added to the conduit run must be
supported.
1.
Welker recommends that the probe be installed in the top of the pipe and inserted into the center one-third (¹⁄₃) of the
pipeline in a location where the product is well-mixed and will yield an accurate and representative sample.
2.
The sample probe should be located in the least turbulent area of the flowing stream (i.e., not in a header or
blow-down stack and away from obstructions, elbows, and partially closed valves).
2.2 Preparing for Installation
To watch a short video of these instructions, scan the QR code below or go to
welker.com/videos/EssentialsGasSampler_
1.
Prior to installing the Essentials™ Gas Sampler to the pipeline, the gauge assembly and sample outlet tubing must be
installed (
Figure 3: Gauge and Tubing Assemblies
SECTION 2: INSTALLATION & OPERATION
8
IOM-222
MODEL: ESSENTIALS™ GAS SAMPLER
REV: A