EXPLANATION

Input bridge rectifier .

To check the Input bridge rectifier , carry out the following
measurements with a diode tester:

Should there be a short circuit on one of these measure-
ments, the input bridge rectifier must be replaced.

To check the inverter, carry out the following measure-
ments with a diode tester:

Should there be a short-circuit on one of these measure-
ments  or  an  “OL”  instead  of  a  numeric  value,  the  power
board must be replaced.

Make sure the two terminals of the thermal devices are
well inserted in the 8-pin white connector on the power
board 0070.

Rheofore 

Probe 

Rheofore 

Probe 

Measure

F+ 

Red 

Black 

“OL”

F− 

Red 

Black 

0.5

F+ 

Black 

Red 

0.5

F− 

Bleck 

Red 

“OL”

P

IC

T

U

R

E

 3

P

IC

T

U

R

E

 4

Red Probe 

Black Probe 

Measure

>2.00

>2.00

P

IC

T

U

R

E

 5

IMPUT RECTIFIER

F-

F+ 

D

G

G

G

G

S

S

S

Содержание WEM221ACDC

Страница 1: ...Operators Manual WEM221ACDC...

Страница 2: ...protection devices of the line set off when the switch is activated and the machine does not go on Damaged power supply cable with short circuited wires Inverter is damaged Switch off the machine and...

Страница 3: ...nel board 0015 and or Power board 0070 and or Inversion board 0071 are damaged Switch off the machine and disconnect the plug Connect the cables 0075 or if they are damaged replace them picture 7 Conn...

Страница 4: ...valve wiring The solenoid valve control relay on the front panel is damaged No 24 V Solenoid valve is damaged Remove the gas connection Carry out a gas test on the front panel in the TIG pro cedure an...

Страница 5: ...ne set The slope up and slope down are not cor rectly set Regulate in the correct way the slopes Otherwise reset the parameters and reset the machine Picture 9 The output voltage in MMA TIG is zero an...

Страница 6: ...explode causing a short circuit most of the times If the extent of the short circuit is very high they become an open circuit To check the PFC of the switching power supply unit carry the following me...

Страница 7: ...erter carry out the following measure ments with a diode tester Should there be a short circuit on one of these measure ments or an OL instead of a numeric value the power board must be replaced Make...

Страница 8: ...a 19 di 35 EXPLANATION Make sure that the fan cables 24 V are correctly in serted 2 pin connector on the power board 2 pin connector on the fan Make sure that the output filter board 0074 cables are c...

Страница 9: ...ways be measured Press S3 and S5 while switching on the machine until appears RECALL FACTORY SETUP After that confirm the parameter resets by pressing the S2 button Copper bar Probe Copper bar Probe M...

Страница 10: ...st Update Letzte Veraenderung 23 04 2014 Rev1 pagina 21 di 35 EXPLANATION Check continuity with a diode tester between points A B of the power board and x y poles of the connector that goes to the fro...

Страница 11: ...221 AC DC Ultima modifica Last Update Letzte Veraenderung 23 04 2014 Rev1 pagina 22 di 35 EXPLANATION 4 pin connector 24V PICTURE 11...

Страница 12: ...221 AC DC Ultima modifica Last Update Letzte Veraenderung 23 04 2014 Rev1 pagina 35 di 35...

Отзывы: