Page 11
2-4. Electric service guide(230V)
CAUTION
WARNING:THIS WELDING MACHINE MUST BE
CONNECTED TO POWER SOURCE IN ACCORDANCE WITH APPLICABLE
ELECTRICAL CODES
AVERTISSEMENT: LE RACCORDEMENT DE CETTE MACHINE DE SOUDAGE Á
L’ALIMENTATION DOIT ÉTRE CONFORME AUX CODES D’
ÉLECTRICITÉ
PERTINENTS
Input voltage(V)
230
Frequency(Hz)
60
Input Amperes at rated output(A)
14
15
Max recommended standard fuse
Rating in Amperes
Circuit breaker, time delay
Normal operation
20
Min input conductor size in AWG
12
Min Grounding conductor Size in AWG
8
Table 2.1
2-5. Extension Cable Selection Chart
CAUTION
USE SHORTEST CABLE POSSIBLE
Input Conductor Size in
AWG (mm
2
)
Maximum Cord Length allowed in Ft(M)
115V
230V
13(2.63) 19(6) 59(18)
11(4.17) 37(11) 120(37)
9(6.63) 62(19) 194(59)
7(10.55) 91(28) 269(82)
5(16.76) 134(41) 393(120)
Table 2.2
2-6. Electric service guide(115V)
The Auto-Line circuitry in this unit automatically links the power source to the primary
voltage being applied, either 115 or 230 VAC.
For 115 volts AC input power, a 15 or 20 Ampere individual branch circuit protected by
time-delay fuses or circuit breaker is required.