32
© Weldclass 2020 | E.&O.E.
7.1.3
Gasless Welding Setup
1.
Connect the earth cable quick connector to the Positive Dinse Socket.
2.
Connect the earth clamp to the work piece. Contact with the work piece must be firm contact
with clean, bare metal, with no corrosion, paint or scale at the contact point.
3.
Connect the MIG Torch Polarity Change Tail to the Negative Dinse Socket (for 210MST) or
Negative Torch Terminal (260MST).
Note
: if this connection is not made, there will be no electrical connection to the welding torch!