![Weldclass CutForce 41PA Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/weldclass/cutforce-41pa/cutforce-41pa_operating-instructions-manual_954311011.webp)
Cutforce 43
P /
41
PA
© Weldclass 2020 | E.&O.E.
11
4.6
Compressor Error Light (41PA model only)
The Compressor Error Light illuminates Red when there is a fault with the built-in compressor.
This can mean that the compressor has over-heated and needs to be allowed to cool. If the error light
does not turn off when the machine has been allowed to cool then this likelihood is that it is a more
serious fault which possibly requires the compressor to be replaced. In this case please contact your
Weldclass distributor to arrange inspection and repair.
5
POWER & COMPRESSED AIR SUPPLY
5.1
Electrical Connection
The Cutforce 43P and 41PA are designed to operate on a 15A 240V AC power supply.
5.2
Extension Leads
If an extension cord must be used, it should be minimum cable core size 2.0mm
2
for length of up to
10m, or minimum 2.5mm
2
for lengths over 10m.
Using extension leads of over 20m are not recommended.
5.3
Generator Use
This machine is designed with generator use in mind and incorporates wide voltage tolerance and
intelligent voltage sensing technology to provide maximum protection from power fluctuations that
can occur with motor generators.
5.3.1
Generator Size
Generator size should be not less than 8kva. An 8kVa generator will not provide enough power to
enable full output and duty cycle of this plasma cutter. However, it should provide sufficient power
for light cutting and short runs.
Turning the amperage down to 30 or 35A will significantly reduce power consumption with little
impact on cutting performance so this is recommended if power supply is lower/limited.
To enable full output and duty cycle of this plasma cutter a recommended generator size is
minimum 10kVa.
5.3.2
Generator Quality & Warranty Limitations
Avoid using poor, low quality generators as these have the greatest risk of power spikes etc. A
suitable quality generator should have a THD (total harmonic distortion) rating of no more than 6%.
Most reputable generator suppliers will be able to specify the THD ratings on their product.
Any damage caused by poor quality generator power supply or incorrect use is not covered under
warranty.
Содержание CutForce 41PA
Страница 19: ...Cutforce 43P 41PA Weldclass 2020 E O E 19 Figure 15...
Страница 21: ...Cutforce 43P 41PA Weldclass 2020 E O E 21...
Страница 22: ...22 Weldclass 2020 E O E 8 6 Primary Schematic Circuit Diagram for 43P Figure 16...
Страница 23: ...Cutforce 43P 41PA Weldclass 2020 E O E 23 8 7 Primary Schematic Circuit Diagram for 41PA Figure 17...
Страница 36: ...36 Weldclass 2020 E O E www Weldclass com au...