2.20 Electrical 

Power

2.21  Power Source Review
 

Review the power source and the voltage rating on the units serial number tag to be sure 
they agree in voltage, phase and frequency. Serious damage may occur to the system if it is 
connected to an improper voltage. All Welch systems must be grounded. Grounding reduces 
the risk of electric shock in the event of an electrical short circuit. The plug must be plugged 
into an outlet properly grounded. Consult your local electrical codes if you have doubts.

2.22 Overload 

Protection

 

The motor manufacturer makes motor thermal overload protection available as an aid to 
minimize motor failure. Overload protection is a standard feature on both 50/60Hz single-
phase motors. The motors have automatic overload protection. Automatic reset protection is 
designed to reset itself after a predetermined cooling period. If the fault to the drive remains 
unaltered, the motor will cycle on and off until fault is corrected.

2.23 Identifi cation Symbols:

 Power Off 

 Power On

2.24 Grounding 

Instructions

 

This product should be grounded. In the event of an electrical short circuit, grounding reduces 
the risk of electric shock by providing an escape wire for the electric current. This product 
is equipped with a cord having a grounding wire with a grounding plug. The plug must be 
plugged into an outlet that is properly installed and grounded in accordance with all local codes 
and ordinances. This adapter shown in Figure B and Figure C is not acceptable in Canada.

   

DANGER

Improper installation of the grounding plug can result in a risk of 

electrical shock. 

 

If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to 
either fl at blade terminal. The wire with insulation having an outer surface that is green with or 
without yellow stripes is the grounding wire. Check with a qualifi ed electrician or serviceman 
if the grounding instructions are not completely understood, or if in doubt as to whether the 
product is properly grounded. Do not modify the plug provided; if it will not fi t the outlet, have 
the proper outlet installed by a qualifi ed electrician.

Содержание 2562C-02

Страница 1: ...g acid base or organic vapors or gases Warning Be sure to properly identify intake and discharge before using pump Part No 642803A Printed in USA Welch Ilmvac 5621 W Howard Street Niles IL 60714 Phone...

Страница 2: ...NTS Page No 1 Safety Information 3 2 Installation 5 3 Operation 8 4 Maintenance 8 5 Trouble Shooting 9 6 Specifications 9 7 Dimensional Drawings 10 8 Application Information 11 9 Exploded Parts List 1...

Страница 3: ...ons are found where failure to observe the instruction could result in damage to the equipment associated equipment and process These units conform to the SI International system of units of measureme...

Страница 4: ...e potential of the pump head bursting and causing possible injury to personnel in the area I 17 All electrical products generate heat To avoid serious burns never touch unit during or immediately afte...

Страница 5: ...plane 2 13 Pump Location and Environmental Condition The pressure vacuum pump should be located in a clean dry and well ventilated area Do not block the ventilation ports located on the motor housing...

Страница 6: ...Identification Symbols Power Off Power On 2 24 Grounding Instructions This product should be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by provi...

Страница 7: ...sure tends to vary from day to day As a result of variability the dial vacuum gauge will indicate slightly different maximum vacuum readings from day to day 2 30 Traps 2 30a The need for a Trap The pu...

Страница 8: ...ection The importance of eliminating all leaks in a vacuum system is obvious The pump must remove this added volume of leaked gas to maintain the desired vacuum Leaks for these pumps can be located by...

Страница 9: ...the intake and reading the vacuum level on the gauge See Section 2 8 5 11 Troubleshooting Guide Poor Pumping Speed Poor Vacuum Loud Unit Possible Cause Corrective Action X X X Damaged Valves Replace...

Страница 10: ...peed Curves 244 0 CORD ASSY 8 25 4X 8 32 UNC 2B THRU 7 09 6 67 9 45 INTAKE NIPPLE FOR 3 8 TUBING MUFFLER 11 67 OUTLET INLET 182 6 3 50 5 38 7 19 296 4 240 0 209 5 9 61 180 0 169 4 88 9 136 6 6 12 Dime...

Страница 11: ...rt No Description 1 61 3576 Jar Lid Intake Machined 1 61 5142 Needle Valve 1 61 5148 Knob 1 624280 Hose Barb Fitting 1 624282 Hose Barb Fitting 1 66 0136 Hose Barb Fitting Straight 1 638788 Vacuum Gau...

Страница 12: ...nt maximum vacuum readings from day to day The preset vacuum level may be adjusted by opening or closing the orifice A small leak through the orifice is provided to allow easy restart of the pump if y...

Страница 13: ...04 Feet Kit 2500K 04 Muffler Kit 1412C 1 2 666544 Connecting Rod Ass y 2 2 2 621755 502 Valve Plate Assembly 2 3 2 628071 Cylinder O ring 2 2 4 2 623143 Valve Plate Gasket 2 2 5 1 641255 Exhaust Muff...

Страница 14: ...pressed or implied The method of executing this warranty servicing adjusting repairing or replacing shall be at the discretion of Welch Ilmvac Vacuum pumps that have been operated within a vacuum syst...

Отзывы: