background image

Screen elements

The liquid crystal display (LCD) displays the following: systolic blood pressure (mmHg),

diastolic blood pressure (mmHg), pulse rate (bpm), heart beat (regular or irregular) while

acquiring blood pressure measurements, excessive motion alert, 

Bluetooth

 connectivity

status or data transmission error, alarm priority, and battery charge level.

Symbol

Description

Systolic blood pressure result
mmHg = measurement unit of the blood pressure

Diastolic blood pressure result
mmHg = measurement unit of the blood pressure

Pulse in beats per minute

Irregular heartbeat
Monitor is detecting an irregular heartbeat during measurement

Heart beat
Monitor is detecting a heartbeat during measurement

Battery indicator
Indicates the current battery charge

Low battery indicator
Indicates the current battery charge

Directions for use 

Introduction  9

Содержание 901042

Страница 1: ...Welch Allyn Remote Monitoring Blood Pressure Device RPM BP100SBP Directions for use 901042 Automated Blood Pressure System Software Version 1 X...

Страница 2: ...Welch Allyn or its vendors All rights are reserved The software is protected by United States of America copyright laws and international treaty provisions applicable worldwide Under such laws the lic...

Страница 3: ...e 11 Overview 11 Set up your equipment 11 Position the blood pressure cuff 13 Start the measurement 14 Blood pressure facts pointers and best practices 16 Maintenance and troubleshooting 19 Maintain t...

Страница 4: ...iv Contents Welch Allyn Remote Monitoring Blood Pressure Device RPM BP100SBP...

Страница 5: ...s of reliable service Readings taken by the monitor are equal to those obtained by a trained observer using the cuff and stethoscope auscultation manual method This Directions for use contains importa...

Страница 6: ...d result in damage to the equipment or other property or loss of data Follow instructions directions for use DFU mandatory action Power symbols Direct current Power Shipping storing and environment sy...

Страница 7: ...nce Minimum Maximum Lot code Not made with natural rubber latex Miscellaneous symbols Type BF applied part Serial number Product Identifier Manufacturer Reorder number Model number Non ionizing electr...

Страница 8: ...nt or other property or loss of measurement data Warnings and cautions Warning Patient injury risk The device is not suitable for measuring the blood pressure of neonatal infants or children Warning P...

Страница 9: ...sk Do not use the unit if you are allergic to polyester or synthetic materials Warning Patient injury risk Excessive tube lengths could cause strangulation if you don t manage them properly Warning Pa...

Страница 10: ...is directions for use Otherwise you will compromise the device s performance and reduce its lifetime CAUTION Do not attempt to repair the unit yourself if it malfunctions Only have repairs carried out...

Страница 11: ...ff to the air connector plug 3 Air connector plug Air tube connects to the air connector plug 4 Power button Powers on the monitor starts and stops a blood pressure measurement and when pressed for 2...

Страница 12: ...rtment behind cover Houses 4 AA alkaline batteries Power options CAUTION To get optimal performance and protect your monitor use only the correct batteries or the Welch Allyn approved power adapter Th...

Страница 13: ...and battery charge level Symbol Description Systolic blood pressure result mmHg measurement unit of the blood pressure Diastolic blood pressure result mmHg measurement unit of the blood pressure Pulse...

Страница 14: ...220mmHg The symbol may appear in either the SYS or DIA area of the screen Alarm priority Low an appears near the top of the screen Reading out of range Either SYS 50mmHg or DIA 25mmHg The symbol may a...

Страница 15: ...r blood pressure measurements you also need a smartphone or tablet with Bluetooth wireless connectivity and the app or software to receive your patient data Set up your equipment Insert or replace the...

Страница 16: ...r connector plug 3 Confirm that the air tube connector locks into place Listen for a click When the air tube connector is properly seated you cannot pull it off the air connector plug Note You may lea...

Страница 17: ...d in discoverable mode ready for pairing Note Bluetooth wireless connectivity is only available for devices which support Bluetooth 4 0 technology 2 Press and hold the Power button on the blood pressu...

Страница 18: ...arm on a flat surface e Ensure the cuff is level with your heart right atrium f Rest for 5 minutes after sitting down and positioning the blood pressure cuff 2 Verify that the cuff is positioned corr...

Страница 19: ...me on the same upper arm or as directed by your physician Some points to remember about your blood pressure device After 10 seconds of inactivity the device powers down If you press and release the Po...

Страница 20: ...heartbeat was detected during measurement Usually this is NOT a cause for concern However if the symbol appears often we recommend you seek medical advice The device does not replace a cardiac examina...

Страница 21: ...n the upper arm Proper cuff tightness No clothing under the cuff or restricting circulation above the cuff Proper posture feet flat on the floor back straight legs uncrossed arm resting on a flat surf...

Страница 22: ...18 Measuring blood pressure Welch Allyn Remote Monitoring Blood Pressure Device RPM BP100SBP...

Страница 23: ...lcohol 10 chlorine bleach 90 water solution standard bleach wipe 2 If necessary you may wipe the cuff with a soft damp cloth Troubleshooting This section includes a list of error messages and frequent...

Страница 24: ...r EE and E 19 shows Malfunctioning hardware Measure again If the problem persists contact the retailer or Welch Allyn customer service at www welchallynhome com for further assistance Physiological al...

Страница 25: ...scillometric testing mode Measurement range Rated cuff pressure 0mmHg to 300mmHg 0kPa to 40kPa Measurement pressure SYS 50mmHg to 260mmHg DIA 25mmHg to 220mmHg Pulse value 40 to 199 beats per minute A...

Страница 26: ...is subject to the following two conditions This device may not cause harmful interference This device must accept any interference received including interference that may cause undesired operation T...

Страница 27: ...et appareil doit tre install dans un emplacement o les antennes de l appareil sont au moins 20 cm de distance de toute personne L utilisation d antennes et de types d antennes gain sup rieur non garan...

Страница 28: ...magnetic compatibility IEC EN 60601 1 2 Medical electrical equipment Part 1 2 General requirements for basic safety and essential performance Collateral standard Electromagnetic compatibility Requirem...

Страница 29: ...ic equipment RF emissions CISPR 11 Class B The Welch Allyn Home Blood Pressure Monitor is suitable for use in all establishments other than domestic establishments and those directly connected to the...

Страница 30: ...C mains voltage prior to application of the test level Electromagnetic immunity The Welch Allyn Home Blood Pressure Monitor is intended for use in the electromagnetic environment specified below The c...

Страница 31: ...sure Monitor bOver the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m Recommended separation distances between portable and mobile RF communications equipment and the Welc...

Страница 32: ...t and the Welch Allyn Home Blood Pressure Monitor Note 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects a...

Страница 33: ...nance contrary to labeled instructions 3 alteration or repair by anyone not authorized by Welch Allyn and 4 accidents The product warranty is also subject to the following terms and limitations Access...

Страница 34: ......

Отзывы: