THERMISTOR CHART
Importar
If the ohmmeter reads “OL,” check the scale setting on
the meter before assuming the thermistor is bad.
Temperature of Thermistor
Resistance
°C
°F
K Ohms (x1000)
-7 - -1.0
19 - 30
47.06 - 34.36
0.0
32
32.65
0.5
33
31.82
1.0
33.8
31.03
1.1
34
30.85
1.5
34.7
30.25
2.0
35.6
29.49
2.5
36.5
28.76
3.0
37
28.05
3.5
38
27.36
4.0 - 10.5
39 - 51
26.68 - 19.43
11.0 - 15.0
52 - 59
18.97 - 15.71
15.5 - 20.0
60 - 68
15.35 - 12.49
20.5 - 25.0
69 - 77
12.21 - 10.00
25.5 - 30.0
78 - 86
9.78 - 8.05
30.5 - 35.0
87 - 95
7.88 - 6.39
36.5 - 40.0
98 - 104
6.14 - 5.32
40.5 - 46.0
105 - 115
5.22 - 4.20
NOTE: The control board will default to a 3.75 minute
pump delay in the freeze cycle, whenever the thermistor is
disconnected or reads outside the resistance ranges in the
table.