HIGH EFFICIENCY DECATHLON FPLHDC65 GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-13
1.7.3 Replacing the Temperature Probe; Controller-equipped Fryers
1.
Disconnect the fryer from the electrical
supply.
2.
Drain cooking oil from the frypot. Allow the
frypot to cool completely before
proceeding.
3.
Remove fryer door for easier access to
the temperature probe. First, remove top
hinge from bracket. Then, lift door off
bottom hinge pin.
4.
Disconnect the probe harness connector
(arrow). Use a pin pusher to remove plug
from probe wires (probe side only). Retain
the plug for re-assembly on new probe.
5.
Remove the drain manifold. Only the
drain tubes directly blocking the frypot
being replaced require removal.
-
Remove the nuts holding the drain
valve strap onto the drain tube stud.
-
Disconnect the Teflon tube at the back
of the center dump tube piece and any
other components attached to the
tubes, including drain flush flexlines.
-
Loosen the nut on each clamp holding
the rubber boots and drain sections
together.
-
Carefully remove the tubes by pulling
down at an angle, straight out of the
Remove the nuts, Teflon tube (not pictured), clamp,
boot, and drain tubes.
Disconnect the two-pin probe harness
connector (arrow).
Remove the fryer door for easier access to the
temperature probe.