EXTERIOR CLEANING

Notice

 

Never use an acid based cleaning solution on exterior 

panels! Many food products have an acidic content, 

which can deteriorate the finish. Be sure to clean the 

stainless steel surfaces of ALL food products.

Clean the area around the unit as often as necessary to 

maintain cleanliness and efficient operation.
Wipe gasket and surfaces with a damp cloth rinsed in water 

to remove dust and dirt from the outside of the unit. Always 

rub with the “grain” of the stainless steel to avoid marring 

the finish. If a greasy residue persists, use a damp cloth 

rinsed in a mild dish soap and water solution. Wipe dry with 

a clean, soft cloth.
Never use steel wool or abrasive pads for cleaning. Never 

use chlorinated, citrus based or abrasive cleaners.
Stainless steel exterior panels have a clear coating that 

is stain resistant and easy to clean. Products containing 

abrasives will damage the coating and scratch the panels. 

Daily cleaning may be followed by an application of 

stainless steel cleaner which will eliminate water spotting 

and fingerprints. Early signs of stainless steel breakdown 

are small pits and cracks. If this has begun, clean thoroughly 

and start to apply stainless steel cleaners in attempt to 

restore the steel.

PLEXIGLAS, INCLUDING BAFFLES

Wet a clean cloth with lukewarm water and dishwashing 

liquid. Apply only light pressure, rinse with clean water 

and blot dry with a damp chamois. For excessively dirty 

surfaces, rinse surface dirt off before washing. Fine 

scratches will disappear when you polish by hand with a 

plastic cleaner polish.

Notice

 

Never use window sprays, kitchen scouring compounds 

or solvents such as acetone, gasoline, benzene, alcohol, 

carbon tetrachloride or lacquer thinner to clean 

plexiglas.

SLIDING DOORS

Frequent, regular cleaning with a mild soap and water 

solution will keep the tracks free of foreign matter and will 

insure many years of service. The glass may be cleaned 

with one of the many commercial glass cleaners currently 

available.

DRAIN

Each unit has a drain located inside the unit that removes 

the condensation from the evaporator coil and routes it 

to an external condensate evaporator pan. Each drain can 

become loose or disconnected during normal use. If you 

notice water accumulation on the inside of the unit, be sure 

the drain tube is connected to the evaporator drain pan. 

If water is collecting underneath the unit, make sure the 

end of the drain tube is in the condensate evaporator. The 

leveling of the unit is important as the units are designed to 

drain properly when level. Be sure all drain lines are free of 

obstructions.

CLEANING THE CONDENSER COIL

In order to maintain proper refrigeration performance, the 

condenser fins must be cleaned of dust, dirt and grease 

regularly. It is recommended that this be done monthly. If 

conditions are such that the condenser is totally blocked 

in a month, the frequency of cleaning should be increased. 

Clean the condenser with a vacuum cleaner or stiff brush. If 

extremely dirty, a commercially available condenser cleaner 

may be required.
Failure to maintain a clean condenser coil can initially cause 

high temperatures and excessive run times. Continuous 

operation with a dirty or clogged condenser coil can 

result in compressor failure. Neglecting the condenser coil 

cleaning procedures will void any warranties associated 

with the compressor and cost to replace the compressor.

Содержание Delfield ASM-36P

Страница 1: ...P Series R Original Instructions Installation Operation and Maintenance Manual This manual is updated as new information and models are released Visit our website for the latest manual A Welbilt Bran...

Страница 2: ...Never use flammable oil soaked cloths or combustible cleaning solutions for cleaning nWarning This product contains chemicals known to the State of California to cause cancer and or birth defects or o...

Страница 3: ...wer Voltage Power Cord Chart 8 Installation Instructions 9 Prepare the Cabinet 9 Lower in the ASM 10 Construct an Air Duct 10 Plumbing 11 Leveling 11 Sliding Door Removal And Reinstall 11 Night Securi...

Страница 4: ...erchandisers is located on the mechanical section wall Always have the serial number of your unit available when calling for parts or service Warranty Information Register your product for warranty Ve...

Страница 5: ...93 66cm 48 25 123cm 25 93 66cm 63 48 161cm 46 50 118cm 63 48 161cm 34 50 88cm 38 65 98cm 24 83 63cm 24 87 63cm 12 50 32cm 12 50 32cm 12 50 32cm Plan View ASM 36P Plan View ASM 48P Elevation View ASM...

Страница 6: ...install or operate this equipment in outdoor areas nWarning Remove all removable panels before lifting and installing nWarning If a refrigerated base does not have a condensate evaporator supplied yo...

Страница 7: ...tible locations The flooring under the appliance must be made of a noncombustible material DANGER Risk of fire shock All minimum clearances must be maintained Do not obstruct vents or openings Sides 1...

Страница 8: ...R A separate fuse circuit breaker must be provided for each unit GROUND FAULT CIRCUIT INTERRUPTER Ground Fault Circuit Interrupter GFCI GFI protection is a system that shuts down the electric circuit...

Страница 9: ...um of 14 36cm up from the cabinet bottom inside the partitions 3 The unit requires airflow to the compressor Two louvers are provided with each unit NOTE Any restriction to the proper air flow will vo...

Страница 10: ...e bolts and remove the lifting plates Install plastic plugs in the bolt holes 11 Install the stainless steel pan clip rail below the door track 12 Install the stainless steel pans in the bottom on the...

Страница 11: ...nters a notch and can be lifted higher Tilt the bottom out without removing the top Use the top to gently return the spring to the closed position Remove the door from the top track Sliding Door Reins...

Страница 12: ...l result in unsatisfactory operation of the system Operation An ON OFF switch is located on the left side of the remote control panel Simply turn the switch to ON to begin operation There is a second...

Страница 13: ...nt Press upper left button for 5 seconds Start defrost Press lower left button for 5 seconds Unit goes into stand by mode The display will read Off then a period Press the lower left button again for...

Страница 14: ...er gloves and eye protection and or face shield must be worn Owners and operators are responsible for maintaining the equipment in accordance with the instructions in this manual Maintenance procedure...

Страница 15: ...otice Never use window sprays kitchen scouring compounds or solvents such as acetone gasoline benzene alcohol carbon tetrachloride or lacquer thinner to clean plexiglas SLIDING DOORS Frequent regular...

Страница 16: ...DELFIELD 980 SOUTH ISABELLA ROAD MOUNT PLEASANT MI 48858 800 733 8821 WWW DELFIELD COM 2019 Welbilt Inc except where explicitly stated otherwise All rights reserved Part Number 9291463A 11 21...

Отзывы: