Meaning of the LED‘s
LEDs in cooling mode
LED
"AGITATOR”
during cooling mode
Agitator is switched on
LED "COMPRESSO
R“
permanently on
off
flashing slowly
flashes fast
in case of a fault
Compressor contactor is switched on
Compressor contactor is switched off
- Pause time compressor (pendulum protection)
- Compressor delay / pre-stirring active
- Anti-freezing protection active
- Compressor blocked via digital input
- Fault thermal protection / fault contact
- Phase fault (opt. in connection with ESVAW 003)
LED
"T1” or „T2"
T1 on
T2 on
T2 flashing
Set target temperature for "T1" is active
Set target temperature for "T2" is active
automatic switching back to T1 active, see [P80]]
LEDs in cleaning mode
LED "ERROR
”
flashing
The control is in error mode and must be acknowledged with the
"OFF" button.
LED “END OF CLEANING / TANK EMPTY”
permanent Cleaning successfully finished - tank is ready for further filling.