Connection for fine atomizers
(thermal)
When using a thermal evaporator (all bioactive
sauna heaters), Nhum has to be connected to N
oven and Lhum to WB (water bath) in the oven.
Important!
The terminal
WM
(water shortage) is not
assigned!
Connection for fine atomizers
When using an electronic fine atomizer (AV 50),
Nhum has to be connected to N and L1hum to L1
from the transformer of the finer atomizer.
Note: For an exact description please see the
installation and operating instructions of the fine
atomizer.
Operation and functions
Description of the operating elements
No.1 Operating
switch
No.2 Control
factor
regulator
No.3 Operating status indicator
No.4 Button for temporary operation
Operating display indicators
LED Indicator
Function
color
lights up
Green
X
Control system ready
Red
X
Evaporator working
No indication
6 hours safety cut-out
Important:
For safety reasons, the controller switches off
operation after a period of 6 hours. Resetting is only
possible with the operating switch.
To activate the humidity controller you have to turn
the switch to „ON“. The required humidity can be set
from 10 - 100% with the rotary regulator.
Note:
The actual humidity in the cabin depends on
the size and density of the sauna cabin and therefore
has to be determined by experiment.
Fast-select button
This function serves to prevent oversaturation with
scented essences and salt solutions during a sauna
session. To get full enjoyment from scented
essences and salt solutions we recommend
activating the short-run button „K“ before entering the
sauna (approx. 15 minutes ON time).
Scented atomization
The HC 10 D can be used together with the AV 50 or
AV 10 to atomize scents and fragrances in controlled
mode. To stimulate a good sense of smell it is
important not to use scents and fragrances all the
time (this will only lead to insensitivity) but to observe
fixed periods of non-use. The atomizing periods can
be set with the „H“ button to suit the scent or
fragrance in question.
For details of the optimum period of use, please see
the description issued for the scent or fragrance in
question.
Important!
Use only those fragrances, scented essences
and salt solutions stipulated by the
manufacturer.
Important safety information:
Mis-use may harm your health!
Be sure to observe the doses stipulated!
10
5
GB
Anleitung HC 10_D_mehrp 27.08.1956 10:30 Uhr Seite 10
Содержание HC 10 D
Страница 28: ...SC10T 29 2 4 20 3 3 3 HO7RN F 245 IEC 66 28 RUS 3 2 Anleitung HC 10_D_mehrp 27 08 1956 10 30 Uhr Seite 28...
Страница 29: ...PE N L1 SC 10 T TML5 29 RUS 4 SC10T AC 230 V 50 Hz Anleitung HC 10_D_mehrp 27 08 1956 10 30 Uhr Seite 29...
Страница 32: ...32 Ersatzteilzeichnung HC 10 D I Nr 00012 Anleitung HC 10_D_mehrp 27 08 1956 10 30 Uhr Seite 32...
Страница 42: ...42 Notizen Anleitung HC 10_D_mehrp 27 08 1956 10 30 Uhr Seite 42...