OPERATING INSTRUCTIONS FOR GAMBIT DE-ESSER/COMPRESSOR DS1-MK3
TECHNICAL DATA
Weiss Engineering Ltd., Florastr. 42, CH-8610 Uster
Page 32
+41 44 940 20 06
+41 44 940 22 14
http://www.weiss.ch
Version send:
Bytecount Value
Description
1
F0
Sysex
Header
2
00
Manufacturer's ID
3
30
Manufacturer's ID
4
5A
Manufacturer's ID
5
08
Model ID: $0C = Gambit DS1-MK3
6
0000nnnn
Device ID: -> Midi channel number
7
00000100
message = send version
Message Type 4
8
00000100
OS Version
data
9
00000100
DSP Version
10
00000100
Scale Version
11
00000100
Coeff. Version
12
F7
EOS
EOS
PC programming mode:
Bytecount Value
Description
1
F0
Sysex
Header
2
00
Manufacturer's ID
3
30
Manufacturer's ID
4
5A
Manufacturer's ID
5
08
Model ID: $0C = Gambit DS1-MK3
6
0000nnnn
Device ID: -> Midi channel number
7
00000101
message = pc programming mode
Message Type 5
12
F7
EOS