![WEISS 3RT2017-1BB42 Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/weiss/3rt2017-1bb42/3rt2017-1bb42_manual_953402055.webp)
Manual R06-2016
55 / 172
ROTARY INDEXING TABLE CONTROLLER
EF2...B
INSTALLATION |
6.2 Power Module PM240-2; frame size FSA / FSB
6.2
Power Module PM240-2; frame size FSA / FSB
The following is necessary for a proper assembly of the power module:
•
Mount the power module in a control cabinet.
The control cabinet requires a cooling air flow to protect the components against overheating. Refer to the
Siemens installation manual for calculation of the cooling air flow.
Cooling air short circuits need to be prevented by the installation of appropriate air guide plates.
•
Mount the power module vertically with the mains and motor connections downwards.
Fig. 26: Installation position of the power module
Fig. 27: Setting up of the cooling air flow