30-
Message text
Returns the message text of the log entry. This message has a maximum of 140 characters. If there is no
event logged at the queried index, the string "(not set)" will be returned.
Address
Index 0x0100 (oldest entry) to 0x0109 (newest entry), Subindex 0x02
Data type
StringT(140)
Factory setting
"(not set)"
Example:
A temperature error event returns the message text "Temperature Error. Please check device ".
8.2.3
System Commands
System commands are sent by writing the corresponding code (1 byte) to index 0x02 of the standardized
process parameters (see section 8.2.1). If necessary, the system commands can be sent directly via the con-
figuration software of the IO-Link master. The available commands are listed below.
Restart the gripping module (code 0x80)
This command can be used to restart the gripping module without having to disconnect it from the power
supply (warm start).
All process parameters configured will be lost during a warm start!
Reset to factory settings (code 0x82)
This command can be used to reset the configuration of the gripping module to factory settings.
All changed process parameters will be overwritten by the default settings.
8.3
System Events (IO-Link Events)
Table 13describes the system events that can be triggered by the gripping module.
For troubleshooting see chapter 11.4.
Code
Event
Description
0x0000
No Malfunction
No more malfunction. Previous fault conditions were resolved.