3 Operation
18-36
3.6.4 Domestic hot water
Domestic hot
water
DHW setpoint
temperature
DHW temperature for normal and setback operation.
Normal
(factory setting:
50 °C
)
Setback
(factory setting:
40 °C
)
Normal and setback operation can be assigned to spe-
cific times of the day using the DHW program.
With version C only the DHW setpoint temperature for
normal operation is displayed.
DHW
Push
DHW Push is used to cover increased hot water demand,
e. g. during setback operation.
The DHW tank is heated once to the DHW setpoint tem-
perature set for normal operation.
DHW
program
The DHW program is used to stipulate the times of the
day when the DHW tanks is heated to normal temperat-
ure or setback temperature.
Change a time program:
Select week day(s) using the knob and confirm.
Time program can be edited.
Circulation
program
The circulation program is used to stipulate the time of
day when the circulation pump is switched on.
Change a time program:
Select week day(s) using the knob and confirm.
Time program can be edited.
DHW
operating
mode
Deactivate DHW preparation.
On
(factory setting):
DHW preparation activated.
Off
:
DHW preparation deactivated.