6.2.4 Access level
In the access level, the configuration can be adapted relative to the burner type or
version.
In the parameter level, the display mode must be configured to
1
, to enable access
to parameters E0 … E4.
Press [G] and [L/A] simultaneously.
The access level is activated.
Press [+] key.
Parameter
E0
is displayed.
Press and hold [Enter] key and set the parameter using [+] or [–].
Press [+] to reach the next parameter.
Parameters Information
Setting range
E0
Burner type
0
: single fuel burner
1
: dual fue burner
E1
Operating mode
(display only, no adjust-
ment possible)
0
: intermittent operation
1
: continuous operation
E2
Flame sensor type
0
: ionisation electrode or flame sensor FLW
1
: switch input X3:14, flame sensor LFS1/RAR9
2
: flame sensor QRB4
E3
Fan configuration
0
: Off
1
: fan control
2
: fan control with fan monitoring
3
: VSD
4
: fan control according to modulating degree specified
5
: DAU control
6
…
255
: off
E4
Pre-ignition delay
0
…
4094
: the time (seconds) runs down from operating status
09
, then ig-
nition starts
OFF
: ignition only from operating status
15
Содержание WL40Z-A
Страница 1: ...Installation and operating instruction Oil burner WL40Z A 83298002 3 2019 11...
Страница 106: ...Installation and operating instruction Oil burner WL40Z A 14 Notes 83298002 3 2019 11 La 106 112 14 Notes...
Страница 107: ...Installation and operating instruction Oil burner WL40Z A 14 Notes 83298002 3 2019 11 La 107 112...
Страница 111: ...83298002 3 2019 11 La...