Set diffuser
With dimension X = 0mm the indicating bolt is flush with nozzle assembly cover.
Turn screw
1
, until dimension X equals the value determined.
X
1
Determine mixing pressure
Determine the mixing pressure required for the preset combustion heat rating
from the diagram and note down.
4
100
360
380
340
320
300
280
260
240
220
200
180
160
140
120
6
8
10
12
14
16
2
1
3
4
1
Combustion heat rating [kW]
2
Mixing pressure [mbar]
3
Stage 1
4
Stage 2
Guide values, which could vary depend. on comb. chamber resistance.