Installation and operating instruction
Room device WEM-RG1

5 Operation

83310002 1/2017-11 La

11-20

5.2 Display

1

2

3

4

5

6

7

9

8

1

Active mode (e. g. manual operation)

2

Summer setting activated (no heating operation)

3

Setback activated (reduced temperature level)

4

Normal operation activated (normal temperature level)

5

Comfort mode activated (increased temperature level)

6

Fault

(1

7

Current room temperature (standard display); parameters and values

8

Setting mode activated

9

Service note

(2

Faults

(1

 If there is a fault in the system, a warning symbol 

 appears in the display.

If an interlocking fault occurs, the warning symbol flashes, the system goes to lock-
out.

Notify Weishaupt Customer Service or your heating contractor.

Service note

(2

 If the service interval of the condensing boiler has been exceeded, an spanner

wrench 

 appears in the display.

Notify Weishaupt Customer Service or your heating contractor.

Содержание WEM-RG1

Страница 1: ...Installation and operating instruction Room device WEM RG1 83310002 1 2017 11 ...

Страница 2: ...3 2 Technical data 7 3 2 1 Electrical data 7 3 2 2 Ambient conditions 7 3 2 3 Dimensions 7 4 Installation 8 5 Operation 10 5 1 Display and operating unit 10 5 2 Display 11 5 3 ManualOperation 12 5 4 Absence 12 5 5 Party mode 13 5 6 Automatic operation 13 5 7 Set room setpoint temperature 14 5 8 Service level 15 5 8 1 Check assignment 15 5 8 2 Adjusting the room temperature 15 5 8 3 Set brightness ...

Страница 3: ...e following requirements apply This appliance can be used by children 8 years and above as well as by persons with limited physical sensory or mental capacities or lack of experience and know ledge provided they are supervised or have been instructed regarding the safe use of the appliance and understand the resulting danger Children must not play with the appliance Cleaning and operator maintenan...

Страница 4: ... be attributed to one or more of the following causes non approved application non observance of the manual operation with faulty safety equipment continual operation despite a fault improper installation commissioning operation and service repairs which have been carried out incorrectly the use of non original Weishaupt parts force majeure the installation of additional components which have not ...

Страница 5: ...ly be used in enclosed rooms The installation location must comply with local regulations and must be frost proof Improper use could endanger the health and safety of the user or third parties cause damage to the unit or other material assets 2 2 Safety measures Safety relevant fault conditions must be eliminated immediately 2 3 Disposal Dispose of all materials and components in a safe and enviro...

Страница 6: ...nd operating instruction Room device WEM RG1 3 Product description 83310002 1 2017 11 La 6 20 3 Product description 3 1 Type key WEM RG1 WEM Type Weishaupt Energy Management RG1 Type Room device basic version Version ...

Страница 7: ...17 11 La 7 20 3 2 Technical data 3 2 1 Electrical data Voltage supply DC 15 30 V Consumption max 0 7 W Type of protection IP 20 3 2 2 Ambient conditions Temperature in operation 0 50 C Temperature during transport storage 0 50 C relative humidity max 85 no dew point 3 2 3 Dimensions 80 mm 80 mm ...

Страница 8: ...against accidental restart The electrical connection must only be carried out by qualified electricians Ob serve local regulations If only 2 wires are available on site the connection can be made using the adapter set WEM CAN 2 wire RF RG1 accessory Secure wall bracket 1 to the wall using the screws supplied Feed the wires 2 through and connect the plug to the wiring diagram WEM FA G H L H L 2 1 I...

Страница 9: ...Installation and operating instruction Room device WEM RG1 4 Installation 83310002 1 2017 11 La 9 20 Pull off protective foil ...

Страница 10: ... 11 La 10 20 5 Operation 5 1 Display and operating unit 2 3 5 1 4 Keys 1 Manual Operation ch 5 3 2 Absent ch 5 4 3 Party mode ch 5 5 4 Automatic operation ch 5 6 Dial knob 5 turn select or change values press briefly confirm or save values approx 3 seconds back to standard display abort ...

Страница 11: ...emperature level 6 Fault 1 7 Current room temperature standard display parameters and values 8 Setting mode activated 9 Service note 2 Faults 1 If there is a fault in the system a warning symbol appears in the display If an interlocking fault occurs the warning symbol flashes the system goes to lock out Notify Weishaupt Customer Service or your heating contractor Service note 2 If the service inte...

Страница 12: ...operation Confirm operating mode using the dial knob The operating mode selected is active after approx 3 seconds Example Activate permanent setback operation 5 4 Absence The heating mode can be temporarily interrupted maximum 23 hours During the time set setback operation is activated Press Absence The hour display is displayed flashing Set and confirm hours required using the dial knob After app...

Страница 13: ... active for the time set Example Activate party mode comfort mode for 4 hours Once the time set has elapsed the operating mode previously set is active again Display the time remaining Press Party mode The time remaining is displayed flashing The standard display re appears after approx 30 seconds 5 6 Automatic operation Temperature level according to predetermined time program The time programs c...

Страница 14: ...al knob Display changes to the the setting of the room setpoint temperature The room setpoint temperature set is displayed flashing Set and confirm the required room temperature using the dial knob Room setpoint temperature has been changed Example Increase room setpoint temperature in normal operation from 21 0 C to 22 5 C Following a change the room setpoint temperature at the respective tempera...

Страница 15: ...g unit of the con densing boiler The standard display re appears after approx 30 seconds 5 8 2 Adjusting the room temperature If no optimal placement of the room device is possible or a measurement error is to be compensated the measured room temperature can be adjusted Setting range 5 0 5 0 K Factory setting 0 0 Press Manual operation and Automatic operation simultaneously for ap prox 2 seconds T...

Страница 16: ... Set and confirm value required using the dial knob The value has been saved The standard display re appears after approx 30 seconds 5 8 4 Set brightness in standby mode Adjust the brightness of the display in standby mode Setting range 0 30 Factory setting 0 Press Manual operation and Automatic operation simultaneously for ap prox 2 seconds The service level is activated Turn dial knob until para...

Страница 17: ...a 7 F Faults 11 G Guarantee 4 H Humidity 7 I Illumination 16 Installation location 5 K Key 10 L Liability 4 Light 16 Lockout 11 M Manual operation 12 Measurement error 15 O Operating panel 10 Operating unit 10 P Party mode 13 Protective foil 9 R Room sensor 15 Room setpoint temperature 14 Room temperature 15 S Safety measures 5 Service 11 Service note 11 Spanner wrench 11 Storage 7 T Temperature 7...

Страница 18: ...Installation and operating instruction Room device WEM RG1 7 Notes 83310002 1 2017 11 La 18 20 7 Notes ...

Страница 19: ...83310002 1 2017 11 La ...

Страница 20: ...ww weishaupt de We reserve the right to make changes All rights reserved Water heaters energy storage tanks This attractive program for domestic water heating includes classic water heaters solar storage tanks heat pump storage tanks and energy storage tanks Solar systems The stylish flat plate collectors are the ideal complement for any Weishaupt heating system They are suitable for solar water h...

Отзывы: