5.) Flange 1 :
Inspect the seal 31 pocket at the top and the seal 27
pocket in the nylon sleeve at the bottom. The sleeve and
seal pockets should be in good condition. If not the flange
should be replaced.
6.) Spider 12 :
Visually inspect the fluid discharge areas for erosion and
corrosion. Some wear in these areas is expected. Any
damage in these areas that extends deeper than .06"
renders the parts unusable and they should be replaced.
7.) Cartridge 10 :
Inspect the seal 29 surface where the cartridge fits against
the body 2 . Inspect the seal surface where the main seal
assembly 5 fits. If these surfaces have deteriorated, the
cartridge should be replaced.
Ref. No.
Part No.
Complete Internal Parts Kit
4L23547
5
3A23356
10
3P23295
11
3P23297
12
3P23298
14
3P23308
16
3P23330
17
4P10258
20
P16637
22
P20006
24
P23302
25
P23303
26
P23304
27
P23333
28
P23334
29
P23335
31
P100875
33
P24707
Seal Kit
4L23549
5
3A23356
17
4P10258
20
P16637
22
P20005
24
P23302
25
P23303
26
P23304
27
P23333
28
P23334
29
P23335
31
P100875
FIG. 4
FIG. 5
Ref. No./FIG 5
Part No.
Complete Internal Parts Kit
4L23547
5
3A23356
10 3P23295
11
3P23297
12
3P23298
14
3P23308
16
3P23330
17
4P10258
20
P16637
22
P20006
24
P23302
25
P23303
26
P23304
27
P23333
28
P23334
29
P23335
31
P100875
33
P24707
Seal Kit
4L23549
5
3A23356
1
4P10258
20
P16637
22
P20005
24
P23302
25
P23303
26
P23304
27
P23333
28
P23334
29
P23335
31
P100875
WEIR SPM REPAIR KITS
VII. Service: (Con’t)