39
STEP 2:
Using the Flange Lift Tool, position the Flange Assembly into a vise; tightening it by the packing nut. Rotate the
Flange until it stops turning. This should be sufficient enough rotation on the packing.
Install Flange PolyPack (12) into Flange as shown below. Ensure that the Poly Pack O-Ring side is facing
down towards the Flange when installing