EXL Back Pressure Relief Valve Calibration Guide (Cont.)
Values in this chart should be considered preliminary and if the predicted gas pressure does not produce the
desired set pressure, you may have to adjust the regulator up or down. Some of the factors affecting
performance include ambient and liquid temperature, and the gas media used.
3” EXL Back Pressure Relief Valve Set Pressure vs. Nitrogen Pressure Performance Data
Line
Set
Pressure
PSI
Required
Nitrogen (or gas)
Pressure
PSI
350
0
500
14
1000
28
1500
41
2000
55
2500
69
3000
83
3500
97
4000
110
4500
124
5000
138
5500
152
6000
166
6500
179
7000
193
7500
207
8000
221
8500
234
9000
248
9500
262
10000
276
10500
290
11000
303
11500
317
12000
331
12500
345
13000
359
13500
372
14000
386
14500
400
15000
414