this mode when you power on the NP-610p series, the screen will display a “+” sign at the center of 

the screen. Use a stylus or finger to push the center of the “+” until it moves. The “+” moves to 

upper-left, upper-right, lower -left, lower-right and center. When all five “+” are done the “+” will 

disappear. The Touch Screen parameter will store at Flash Rom.   

 

 

If losing or forgetting system passwords, users can set 

Dip Switch 1 to “ON” position, the rest of Dips remain 

on “OFF” position and then reboot NP-610p series. 

Under this situation, NP-610p series will jump to Touch 

Adjust (Touch screen calibration) mode. After 

calibration, the pop-up window appears as the 

illustration below. Users will be inquired if restoring the 

system password to the default value. 

 

When “YES” is chosen, another pop-up dialog appears 

as below. Users will be confirmed again if restoring the 

system password to the default value and will be asked 

to input “YES”. Then click OK. (The default password 

is 111111. However, other passwords, including 

download and upload password, have to be reset.) 

 

Note: When the reset action is be taken, projects and saved data in the HMI will all be cleared. 

2.4 CE Requirements 

EU directives that apply to the NP-610p Series: 

 

EMC Directive (89/336/EEC, 92/31/EEC, 93/68/EEC) electromagnetic emissions and immunity 

 

Machinery Directive (89/392/EEC, 91/368/EEC, 93/44/EEC, 93/ 68/EEC) machine safety 

 

NP-610p products will be CE-marked to indicate compliance with the EMC Directive.   

 

The NP-610p Series has been designed to operate satisfactorily in electromagnetic noise (immunity) and 
without emitting high levels of electrical noise into the environment (emission). The units are designed to 
meet European Community standards when installed per the wiring instructions in this manual. 
 
Compatibility   
Standards
 

The NP-610p has been designed to meet electromagnetic compatibility for industrial 
environments. 

• CISPR (EN 55011) Group 1, Class A Radiated Emissions levels 

• EN50081-2 Generic emission standard, industrial environment (Also US FCC Class 
A) 

• EN50082-2 Generic immunity standard, industrial environment 

 

 

 

 

 

 

Содержание NP-610p Series

Страница 1: ...the panel during wash downs Electrical Environment The NP 610p Series has been tested to conform to European CE requirements This means that the circuitry is designed to resist the effects of electrical noise This does not guarantee noise immunity in severe cases Proper wire routing and grounding will insure proper operation Mechanical Environment Avoid installing units in environments where sever...

Страница 2: ... are installed correctly and that the operating limits are followed See Specifications Do not operate the unit in areas subject to explosion hazards due to flammable gases vapors or dusts The unit should not be installed where fast temperature variations and or high humidity are present This will cause condensation of water in the device Do not install these terminals in environments where have in...

Страница 3: ...al 2 2 2 Grounding Requirements Chassis ground must be used DC ground is not directly coupled to Earth ground internally It is preferable not to ground DC negative return to chassis ground as poor site earths can introduce noise into a system but if necessary an earth connection should be made from the power supply return point to the central star earth point Ground conductors should be as short a...

Страница 4: ...ation consideration should be given to the use of locks or other means of assuring that only authorized personnel can make such changes These recommendations are intended as safeguards against the failure of critical components and the effects of such failures or the inadvertent errors that might be introduced if programs are changed while the equipment is in operation The ICS 3 304 81 Safety Reco...

Страница 5: ...M3 RS 232 Port Pin Symbol Com1 RS485 2w Com1 RS485 4w Com3 RS485 CAN Bus 1 Rx Data Rx 2 Rx Data Rx 3 Tx Tx 4 Tx Tx 5 GND Signal Ground 6 Data Data 7 Can_L Can_L 8 Can_H Can_H 9 Data Data 2 3 3 USB Host port Support various devices with USB interface such as mouse keyboard USB stick printer etc 2 3 4 Connecter Wire NP 610p Ethernet NP 610p Ethernet RJ45 Wire color 1 TX White Orange 2 TX Orange 3 RX...

Страница 6: ...efault password is 111111 However other passwords including download and upload password have to be reset Note When the reset action is be taken projects and saved data in the HMI will all be cleared 2 4 CE Requirements EU directives that apply to the NP 610p Series EMC Directive 89 336 EEC 92 31 EEC 93 68 EEC electromagnetic emissions and immunity Machinery Directive 89 392 EEC 91 368 EEC 93 44 E...

Страница 7: ...e T USB USB Host port x 1 USB Client port x 1 Processor 32bit RISC CPU 600MHz RAM 128MB Flash memory 128MB SD SDHC card slot Yes RTC Built in General Specification Input Power 24 20 VDC Max Power Consumption 400 mA 24VDC Power Isolation Inside Protection structure NEMA 4 IP65 front panel O ring seal Operating Temperature 0 50 C Operation humidity 10 90 RH non condense Enclosure Plastic Dimensions ...

Страница 8: ...intek the product fails due to damage from shipment handling storage accident natural and man mad b if the product fails due to misuse including but not limit to incorrect set up and wiring current leakage from machine platform and incorrect input power c if the product has been maintained in a manner not conforming to product s instructions or has been modified in any way d if the serial number h...

Страница 9: ...9 4 0 Dimensions of NP 610p Cutout dimensions ...

Отзывы: