6
this mode when you power on the NP-610p series, the screen will display a “+” sign at the center of
the screen. Use a stylus or finger to push the center of the “+” until it moves. The “+” moves to
upper-left, upper-right, lower -left, lower-right and center. When all five “+” are done the “+” will
disappear. The Touch Screen parameter will store at Flash Rom.
If losing or forgetting system passwords, users can set
Dip Switch 1 to “ON” position, the rest of Dips remain
on “OFF” position and then reboot NP-610p series.
Under this situation, NP-610p series will jump to Touch
Adjust (Touch screen calibration) mode. After
calibration, the pop-up window appears as the
illustration below. Users will be inquired if restoring the
system password to the default value.
When “YES” is chosen, another pop-up dialog appears
as below. Users will be confirmed again if restoring the
system password to the default value and will be asked
to input “YES”. Then click OK. (The default password
is 111111. However, other passwords, including
download and upload password, have to be reset.)
Note: When the reset action is be taken, projects and saved data in the HMI will all be cleared.
2.4 CE Requirements
EU directives that apply to the NP-610p Series:
EMC Directive (89/336/EEC, 92/31/EEC, 93/68/EEC) electromagnetic emissions and immunity
Machinery Directive (89/392/EEC, 91/368/EEC, 93/44/EEC, 93/ 68/EEC) machine safety
NP-610p products will be CE-marked to indicate compliance with the EMC Directive.
The NP-610p Series has been designed to operate satisfactorily in electromagnetic noise (immunity) and
without emitting high levels of electrical noise into the environment (emission). The units are designed to
meet European Community standards when installed per the wiring instructions in this manual.
Compatibility
Standards
The NP-610p has been designed to meet electromagnetic compatibility for industrial
environments.
• CISPR (EN 55011) Group 1, Class A Radiated Emissions levels
• EN50081-2 Generic emission standard, industrial environment (Also US FCC Class
A)
• EN50082-2 Generic immunity standard, industrial environment