The ICS 3-304.81 Safety Recommendations are reproduced by permission of the National Electrical 
Manufacturers Association from NEMA ICS 3-304 

 

2.3 Limited Liability Warranty 

Weintek products include the isolated power supply are covered by a limited liability warranty from defects 

in material and workmanship. This warranty does not apply : (a) if, in the judgment of Weintek, the product 

fails due to damage from shipment, handling, storage, accident (natural and man-mad) ; (b) if the product 

fails due to misuse, including but not limit to incorrect set-up and wiring, current leakage from machine 

platform and incorrect input power ; (c) if the product has been maintained in a manner not conforming to 

product's instructions or has been modified in any way, (d) if the serial number has been defaced or removed. 

 

2.4 Communications Connections 

The ports as you look at the back of the case, are the ports for connecting to a PLC or some external 

device (Controller Connectors). 

 

2.4.1 Connector COM1 [RS232], COM2 [RS232] 

Cable 
Requirements 

Different cables are required for various devices. 

 
Caution 

Restrict cable length to less than 500’ (150m) for RS485/422 devices and 
50’ (15m) for RS232 devices to avoid communications problems.   

The COM light on the front of the MT-8000 will turn on with each Ethernet 
communication. 

Shielded cable must be used for long lengths or cables run in an electrically 
noisy environment. 

Do not run cables next to AC power lines or near sources of electrical noise.   

Be sure that the cable ends have been inserted all of the way into mating 
connectors and are secure 

Pin assignment of the 9 Pin, Male, SUB-D, COM1 [RS-232] and COM2 
[RS-232] Port. 

Pin Designations 

 

COM1 [RS-232] 
COM2 [RS-232]

 

 

Pin#  Symbol 

COM1 [RS232] 

COM2 [RS232] 

1 Not 

used 

 

 

2 RxD  Received 

Data 

 

3 TxD  Transmitted 

Data 

 

4 TxD   

Transmitted 

Data 

5 GND 

Signal 

Ground 

6 RxD   

Received 

Data 

RTS 

Ready to send output 

 

CTS 

Clear to send input 

 

9 Not 

used 

 

 

 

 

 

 

 

 

Содержание MT-8080T

Страница 1: ...ise This does not guarantee noise immunity in severe cases Proper wire routing and grounding will insure proper operation Mechanical Environment Avoid installing units in environments where severe mec...

Страница 2: ...is 24 5 Volts DC This insures compatibility with most controller DC systems The power conditioning circuitry inside the unit is accomplished by a switching power supply The peak starting current can...

Страница 3: ...in Controller systems could fail and thereby create an unsafe condition Furthermore electrical interference in an operator interface such as an MT 8000 can lead to equipment start up which could resu...

Страница 4: ...look at the back of the case are the ports for connecting to a PLC or some external device Controller Connectors 2 4 1 Connector COM1 RS232 COM2 RS232 Cable Requirements Different cables are required...

Страница 5: ...Com1 RS485 4w Com3 RS485 Com3 RS232 1 Rx Data Rx 2 Rx Data Rx 3 Tx Tx 4 Tx Tx 5 GND Signal Ground 6 Data Data 7 TxD Transmit 8 RxD Receive 9 Data Data 2 4 3 USB Host port Support various devices with...

Страница 6: ...000 Under this situation MT8000 will jump to Touch Adjust Touch screen calibration mode After calibration the pop up window appears as the illustration below Users will be inquired if restoring the sy...

Страница 7: ...tandard industrial environment 3 0 Specifications MT8121T MT8104T MT6104T MT8080T Hardware Specification Display 12 1 TFT 10 4 TFT 8 TFT Brightness 400 cd m2 400 cd m2 400 cd m2 Color 65536 colors Con...

Страница 8: ...IC IN COM2 RS232 COM1 RS485 2 4W COM3 RS232 USB HOST GND FG 24V FUS E1A R e set DI P SW Rear View Rear View Rear View 50mm 1 97 50mm 1 97 Bottom View Bottom View Bottom View Cutout dimensions 305mm 12...