      If provision is required for changing programs while the equipment is in operation, consideration should be given to the use 
of locks or other means of assuring that only authorized personnel can make such changes. 
      These recommendations are intended as safeguards against the failure of critical components and the effects of such failures 
or the inadvertent errors that might be introduced if programs are changed while the equipment is in operation.   

z

 

The ICS 3-304.81 Safety Recommendations are reproduced by permission of the National Electrical 
Manufacturers Association from NEMA ICS 3-304 

6

2.3 Communications Connections 

The ports as you look at the back of the case, are the ports for connecting to a PLC or some external 

device (Controller Connectors). 

15

2.3.1 Connector COM1 [RS232], COM2 [RS232] 

Cable 
Requirements 

Caution 

Different cables are required for various devices. Restrict cable length to less than 500’ 
(150m) for RS485/422 devices and 50’ (15m) for RS232 devices to avoid 
communications problems.   

The COM light on the front of the MT-600/8000 will turn on with each Ethernet 
communication. Shielded cable must be used for long lengths or cables run in an 
electrically noisy environment.   

Do not run cables next to AC power lines or near sources of electrical noise. Be sure 
that the cable ends have been inserted all of the way into mating connectors and are 
secure 

Pin assignment of the 9 Pin, Male, SUB-D, COM1 [RS-232] and COM2 [RS-232] Port. 

Pin Designations 

COM1 [RS-232] 
COM2 [RS-232]

 

 

Pin#

Symbol 

COM1 [RS232] 

COM2 [RS232] 

1 Not 

used 

2 RxD  Received 

Data 

3 TxD  Transmitted 

Data 

4 TxD 

Transmitted 

Data 

5 GND 

Signal 

Ground 

6 RxD 

Received 

Data 

RTS 

Ready to send output 

CTS 

Clear to send input 

9 Not 

used 

2.3.2 Connector COM1[RS485] , COM3[RS485] and COM3[RS232] 

The 9 Pin, Female, SUB-D, COM1 [RS-485], COM3 [RS-485] and COM3 [RS-232] Port on the back 

of the unit is the RS-232 and RS485/422 communications port for connecting to a controller.   

4

 

Connection 
Pin Designations 

COM1 [RS-485]

 

COM3 [RS-485] 

COM3 [RS-232]

 

Pin assignment of the 9 Pin, Female, SUB-D COM1 [RS-485], COM3 [RS-485] 
and COM3 [RS-232] Port. COM1 [RS485]2w supports MPI 187.5K. 

Pin#

Symbol Com1 

[RS485]2w 

Com1 
[RS485]4w 

Com3 
[RS485] 

Com3 
[RS232] 

1 Rx- 

Data- 

Rx- 

2 Rx+  Data+ 

Rx+ 

3 Tx- 

Tx- 

4 Tx+ 

Tx+ 

5 GND 

Signal 

Ground 

6 Data- 

Data- 

7 TxD 

Transmit 

8 RxD 

Receive 

9 Data+ 

Data+ 

Содержание MT-6100i

Страница 1: ...d to conform to European CE requirements This means that the circuitry is designed to resist the effects of electrical noise This does not guarantee noise immunity in severe cases Proper wire routing...

Страница 2: ...or high humidity are present This will cause condensation of water in the device z Do not install these terminals in environments where have inflammable gases 5 2 2 Power Connections Make sure that al...

Страница 3: ...ground connection should be run directly to the central star earth connection point as recommended in most Installation Instructions 1 4 2 2 4 Safety Guidelines This section presents recommended inst...

Страница 4: ...600 8000 will turn on with each Ethernet communication Shielded cable must be used for long lengths or cables run in an electrically noisy environment Do not run cables next to AC power lines or near...

Страница 5: ...st time enjoying this function The HMI models MT6050i MT6056i MT6070iH MT6100i MT8070iH and MT8100i 1 Using USB cable mini side plug to HMI and another side plug into PC The PC will display Found New...

Страница 6: ...alibration the pop up window appears as the illustration below Users will be inquired if restoring the system password to the default value z When YES is chosen another pop up dialog appears as below...

Страница 7: ...ess 300 cd m 2 Color 65 536 colors Contrast Ratio 500 1 Resolution WxH dots 800 x 480 Back light LED LED life time 30 000 hr min Touch panel 4 wires resistive type Touch Accuracy Active Area Length X...

Страница 8: ...dimensions MT 8100i 259mm 10 20 W x 201mm 7 91 H 259mm 10 20 201mm 7 91 E L OGO m a rk 1 jpg l Cutout Dimensions MT610i M 259mm 10 20 Wx201mm 7 91 H T6100i MT8100i a N A g USB Client port b USB Host p...

Отзывы: