Installation Instruction 

0

1.0 Installation and Startup Guide 

7

Install Environment 

Where  
Used

 

The MT-600/8000 Series is designed for industrial. The temperature range of operating 
is from 32 to 113 °F (0 to 45 °C) , as majority of industrial environments. It may not 
be suitable for using in certain outdoor applications. Please consult the factory for 
advised usage in outdoor applications. 

NEMA 
Rating 

The MT-600/8000 Series front bezel is NEMA 4 rated. When installed properly in a 
NEMA 4 panel, the NEMA 4 rating of the panel will not be compromised. This means 
that fluids will not enter the panel during wash downs. 

Electrical 
Environment 

The MT-600/8000 Series has been tested to conform to European CE requirements.
This means that the circuitry is designed to resist the effects of electrical noise. This 
does not guarantee noise immunity in severe cases.    Proper wire routing and 
grounding will insure proper operation. 

Mechanical 
Environment 

Avoid installing units in environments where severe mechanical vibration or shocks
are present. 

1

2.0 Installation Instructions 

4

2.1 Mounting Instructions 

8

2.1.1 Location Considerations 

Care should be taken when locating equipment behind the unit to ensure that AC power wiring, PLC 

output modules, contactors, starters and relays, and any other source of electrical interference are located 
away from the back of the unit. 

Particular note should be taken to the position of variable speed drives and switching power supplies. 

Their input and load cables should be screened to a central star earth point. 

1

 

Для заказов: +7(499)707-11-20,  

Email: [email protected]

8-800-511-65-88(Бесплатно по РФ)

Содержание MT-6100i

Страница 1: ...d to conform to European CE requirements This means that the circuitry is designed to resist the effects of electrical noise This does not guarantee noise immunity in severe cases Proper wire routing...

Страница 2: ...or high humidity are present This will cause condensation of water in the device z Do not install these terminals in environments where have inflammable gases 5 2 2 Power Connections Make sure that al...

Страница 3: ...ground connection should be run directly to the central star earth connection point as recommended in most Installation Instructions 1 4 2 2 4 Safety Guidelines This section presents recommended inst...

Страница 4: ...600 8000 will turn on with each Ethernet communication Shielded cable must be used for long lengths or cables run in an electrically noisy environment Do not run cables next to AC power lines or near...

Страница 5: ...st time enjoying this function The HMI models MT6050i MT6056i MT6070iH MT6100i MT8070iH and MT8100i 1 Using USB cable mini side plug to HMI and another side plug into PC The PC will display Found New...

Страница 6: ...alibration the pop up window appears as the illustration below Users will be inquired if restoring the system password to the default value z When YES is chosen another pop up dialog appears as below...

Страница 7: ...ess 300 cd m 2 Color 65 536 colors Contrast Ratio 500 1 Resolution WxH dots 800 x 480 Back light LED LED life time 30 000 hr min Touch panel 4 wires resistive type Touch Accuracy Active Area Length X...

Страница 8: ...dimensions MT 8100i 259mm 10 20 W x 201mm 7 91 H 259mm 10 20 201mm 7 91 E L OGO m a rk 1 jpg l Cutout Dimensions MT610i M 259mm 10 20 Wx201mm 7 91 H T6100i MT8100i a N A g USB Client port b USB Host p...

Отзывы: