4

 

exists and take appropriate precautions. Although the specific design steps 
depend on your particular application, the following precautions generally 
apply to installation of solid-state programmable control devices. In addition, 
these precautions conform to the guidelines for installation of Controllers as 
recommended in the NEMA ICS 3-304 Control Standards. 

Programming 

Considerations 

 

To conform with ICS Safety Recommendations, checks should be placed 

in the controller to ensure that all writable registers that control critical 

parts of plant or machinery have limit checks built into the program, with 

an out-of-limit safe shut down procedure to ensure safety of personnel. 

ICS 3-304.81 Safety Recommendations: 

     

Consideration should be given to the use of an emergency stop function, which is independent of the programmable 

controller. 
      Where the operator is exposed to the machinery, such as in loading or unloading a machine tool, or where the machine 
cycles automatically, consideration should be given to the use of an electromechanical override or other redundant means, 
independent of the programmable controller, for starting and interrupting the cycle. 
      If provision is required for changing programs while the equipment is in operation, consideration should be given to the 
use of locks or other means of assuring that only authorized personnel can make such changes. 
      These recommendations are intended as safeguards against the failure of critical components and the effects of such 
failures or the inadvertent errors that might be introduced if programs are changed while the equipment is in operation. * 

 

z

 

The ICS 3-304.81 Safety Recommendations are reproduced by permission of the National Electrical 

Manufacturers Association from NEMA ICS 3-304 

2.3 Communications Connections 

The ports as you look at the back of the case, are the ports for connecting to a PLC or some external 

device (Controller Connectors).   

2.3.1 Connector COM1 [RS232], COM2 [RS232] 

Cable 

Requirements 

Different cables are required for various devices. 

 

Caution 

Restrict cable length to less than 500’ (150m) for RS485/422 devices and 

50’ (15m) for RS232 devices to avoid communications problems.   

The COM light on the front of the MT6070iH3 will turn on with each 

Ethernet communication. 

Shielded cable must be used for long lengths or cables run in an electrically 

noisy environment. 

Do not run cables next to AC power lines or near sources of electrical noise.   
Be sure that the cable ends have been inserted all of the way into mating 
connectors and are secure. 
Pin assignment of the 9 Pin, Male, SUB-D, COM1 [RS-232] and COM2 
[RS-232] Port. 

Pin Designations 

 
 

 

COM1 [RS-232] 
COM2 [RS-232]

 

 

Pin#  Symbol 

COM1 [RS232] 

COM2 [RS232] 

1 Not 

used 

 

 

2 RxD  Received 

Data 

 

3 TxD  Transmitted 

Data 

 

4 TxD   

Transmitted 

Data 

5 GND 

Signal 

Ground 

6 RxD   

Received 

Data 

RTS 

Ready to send output 

 

CTS 

Clear to send input 

 

9 Not 

used 

 

 

 

Содержание MT-6070iH3 Series

Страница 1: ...es has been tested to conform to European CE requirements This means that the circuitry is designed to resist the effects of electrical noise This does not guarantee noise immunity in severe cases Proper wire routing and grounding will insure proper operation Mechanical Environment Avoid installing units in environments where severe mechanical vibration or shocks are present 2 0 Installation Instr...

Страница 2: ... z The MT6070iH3 are to be used indoors as built in displays Make sure that the displays are installed correctly and that the operating limits are followed See Specifications z Do not operate the unit in areas subject to explosion hazards due to flammable gases vapors or dusts z The unit should not be installed where fast temperature variations and or high humidity are present This will cause cond...

Страница 3: ...ot directly coupled to Earth ground internally It is preferable not to ground DC negative return to chassis ground as poor site earths can introduce noise into a system but if necessary an earth connection should be made from the power supply return point to the central star earth point Ground conductors should be as short and as large in size as possible The conductors must always be large enough...

Страница 4: ...only authorized personnel can make such changes These recommendations are intended as safeguards against the failure of critical components and the effects of such failures or the inadvertent errors that might be introduced if programs are changed while the equipment is in operation z The ICS 3 304 81 Safety Recommendations are reproduced by permission of the National Electrical Manufacturers Asso...

Страница 5: ...rnal device 2 3 4 USB Client port Mini USB cable RZCMT6100 is used to download projects from PC by the USB 2 0 client port Support USB 2 0 client interface The cable regulation must accord with HI SPEED USB Revision 2 0 SHIELDED Note Please do not connect HMI with PLC and PC simultaneously to prevent potential difference from destroying USB ports of HMI and PC How to install USB driver of HMI i se...

Страница 6: ...d 4 to ON position the rest of Dips remain on OFF position and then reboot MT6070iH3 Under this situation MT6070iH3 will jump to Touch Adjust Touch screen calibration mode After calibration the pop up window appears as the illustration below Users will be inquired if restoring the system password to the default value z When YES is chosen another pop up dialog appears as below Users will be confirm...

Страница 7: ... 2001 A2 2003 3 0 Specifications MT6070iH3 Hardware Specification Display 7 TFT LCD Brightness 350 cd m2 Color 65 536 colors Contrast Ratio 500 1 Resolution WxH dots 800 x 480 Back light LED Backlight life time avg 30 000 hr min Touch panel 4 wires resistive type Touch Accuracy Active Area Length X 2 Width Y 2 I O port COM1 RS 232 RS 485 2W 4W COM2 RS232 COM3 RS 232 RS 485 2W Ethernet port N A USB...

Страница 8: ... product has been maintained in a manner not conforming to product s instructions or has been modified in any way d If the serial number has been defaced or removed 4 0 Dimensions of MT 6070iH3 GME6070I1_MT6070iH3_Installation_120409 a DIP SW Reset button e Com1 RS485 Com3 RS485 Com3 RS232 b Fuse f Com1 RS232 Com2 RS232 c Power connector g USB Host port d VESA 75mm screw holes h USB Client port CO...

Отзывы: