background image

5

 

2.3.2 Connector COM2 [RS232] 

 

Pin Designations 

 

COM2 [RS-232]

 

 

Pin assignment of the 9 Pin, Male, SUB-D COM2 [RS-232] Port 

Pin# Symbol  Function 
1  

 

2 RxD  Received 

Data 

3 TxD  Transmitted 

Data 

4  

 

5 GND  Signal 

Ground 

6  

 

RTS 

Ready to send output 

CTS 

Clear to send input 

9  

 

 
Pin 1,6,8 short. 

 

2.3.3 Connector COM3[RS485] 

     

Pin Designations 

 

COM3 [RS-485]

 

 

 

Pin assignment of the 9 Pin, Female, SUB-D COM3 [RS-485] Port 

Pin#  Symbol 

RS-485 4wire 

RS-485 2wire 

1  

 

 

2 Tx+  Transmitted 

Data+ 

Data+ 

3 Tx-  Transmitted 

Data- 

Data- 

4 Rx+  Received 

Data+  

5 Rx-  Received 

Data-  

GND 

Signal Ground 

Signal Ground 

7  

 

 

8  

 

 

9  

 

 

 

 
 

2.3.4 USB Client port 

    The USB client port for ActiveSync

use a USB client to USB host cable connects the USB client port on 

MT606 and the USB host port on user’s host PC. 

 
Pin Function 
1 N/C 
2 USB_DATA- 
3 U 
4 GND 

 

2.3.5 USB Master port 

    The USB Master port can connect USB mouse and USB keyboard.   

Содержание EasyView MT-600 Series

Страница 1: ...en tested to conform to European CE requirements This means that the circuitry is designed to resist the effects of electrical noise This does not guarantee noise immunity in severe cases Proper wire...

Страница 2: ...le gases vapors or dusts z The unit should not be installed where fast temperature variations and or high humidity are present This will cause condensation of water in the device z Do not install thes...

Страница 3: ...st always be large enough to carry the maximum short circuit current of the path being considered Ground conductors should be connected to a tree from a central star earth ground point This ensures th...

Страница 4: ...ht be introduced if programs are changed while the equipment is in operation z The ICS 3 304 81 Safety Recommendations are reproduced by permission of the National Electrical Manufacturers Association...

Страница 5: ...5 Pin assignment of the 9 Pin Female SUB D COM3 RS 485 Port Pin Symbol RS 485 4wire RS 485 2wire 1 2 Tx Transmitted Data Data 3 Tx Transmitted Data Data 4 Rx Received Data 5 Rx Received Data 6 GND Sig...

Страница 6: ...EC electromagnetic emissions and immunity z Machinery Directive 89 392 EEC 91 368 EEC 93 44 EEC 93 68 EEC machine safety z MT500 products will be CE marked to indicate compliance with the EMC Directiv...

Страница 7: ...Hz DRAM 64MB Storage 32MB Flash memory on board 1 CompactFlash card slot RTC Yes General Specification Input Power 21 25 VDC Power Consumption 350 mA 24VDC CE Complies with EN50081 2 and EN50082 2 sta...

Страница 8: ...B client b Sound ports h USB Master c MIC ports i Com1 RS232 d Ethernet port RJ 45 j Com2 RS232 e Fuse k Com3 RS485 f Power connector Front View Side View Cutout dimensions MT 608S 222mm 8 74 W x 167m...

Отзывы: