12
Sizes and bracket recommendations
Planning/measuring
Pitch
Patio depth in cm
150
200
250
300
350
400
5°
150
200
250
300
350
400
15°
150
210
260
310
360
410
25°
160
220
270
330
390
440
Pitch
Diagonal in cm
150
200
250
300
350
400
5°
270
270
260
260
250
250
15°
240
230
220
210
200
180
25°
220
200
180
160
140
110
Wall mounting on C20/25 concrete with up
to 200 mm facing, wind resistance class 2 and
a permissible centric tensile load of 5.71 kN
for anchor bolts
Standard wall brackets (85 mm)
Width
in cm
Number of
arms
Diagonal in cm (irregular fi gures possible)
150
200
250
300
350
195 – 200
2
2
201 – 250
2
2
2
251 – 300
2
2
2
2
301 – 350
2
2
2
2
2
351 – 400
2
2
2
2
2
2
401 – 450
2
3
3
3
3
5
451 – 500
2
3
3
3
3
5
501 – 550
2
3
3
3
3
5
551 – 600
2
3
3
3
5
5
601 – 650
2
5
5
5
5
5
651 – 700
3
7
7
7
7
7
Ins
tall
a
tion
h
eight
Patio depth
Cle
a
ranc
e he
ight
Diagon
al
Pitch
This table is used to find the clear-
ance heights for various diagonals
when the tilt angle is 5°, 15° or 25°.
This table is based on the example
of an installation height of 300 cm
(upper edge of awning).
Determining the diagonal
Determining the clearance height
This table can be used to find the
awning diagonal for any given
horizontal patio depth.
Diagonal in cm (rounded fi gures)
Clearance height in cm (rounded fi gures)
Determining the diagonal and clearance
height:
1. Find the diagonal by looking in the ‘diagonal’
table for the patio depth.
2. Using the diagonal from the table and the
required pitch, consult the ‘clearance height’
table for the clearance height. This clearance
height refers to a mounting height of 300 cm.
3. Add/subtract the diff erence between 300 cm
and the actual mounting height to/from the
clearance height in the table.
Содержание Semina
Страница 1: ...www weinor com Semina The youthful semi cassette awning...
Страница 7: ...7...
Страница 8: ...8...