Weil-McLain

500 Blaine Street

Michigan City, IN  46360-2388

http://www.weil-mclain.com

550-110-762/0400

Support bare tubing

Place return pipe in
cradle provided by
bracket, as shown.

Support bare supply
tubing from bracket
using wire hangers,
(not supplied).

Holes for risers & connectors

Drill 1½" holes for risers or connectors

Solder elements to risers
and to any additional
tubing that may be
required.

When attaching radiant tubing,
solder connectors and let cool
before attaching tubing. Follow all
tubing manufacturer's instructions.

1C\,

" from wall

1C\,

" from wall

2 >\zn

"  above

finished floor

Install damper

Place open end of
damper onto bracket
half rounds.

Press down and inward
to snap onto bracket.

a

b

Install front cover

Hook bottom lip of
front cover under
lower bracket arm
as shown.

If cover does not fit
snugly, bend lower
bracket arm down
and reinstall front
cover.

a

b

Lift the front cover
until top lip of cover
snaps over top prong
of bracket.

Install element

Place element on
brackets as shown.

Assemble multiple
elements by soldering
the male end on one
element into the female
end of another.

For horizontal runs of
more than 30 feet,
install expansion
joints.

Ratings

Ratings

 Notes:

 Notes:

I=B=R approved water ratings are based on the active (finned) length and 
include the 15% addition for heating effect allowed by the I=B=R Testing 
and Rating Code for Baseboard Type of Radiation.  The active length is 3" 
less than the enclosure length.  Ratings apply to the assembly with the 
damper installed and adjusted to the normally open position.

The heating elements are constructed of 3/4" nominal copper tubing 
expanded into 1 7/8" x 2 11/32" aluminum fins, which are spaced 67 to the 
foot; fin thickness is .008". Elements are unpainted.

Use of I=B=R ratings at the 4 gpm flow rate is limited to installations in 
which the water flow rate through the baseboard unit is equal to or greater 
than 4 gpm. Where the water flow rate is not known, the I=B=R ratings at 
the standard flow rate of 1 gpm must be used. Flow rates exceeding 6 
gpm should be avoided because of possible noise.

Pressure drop through Therma Trim Baseboard is 0.047" of water per 
linear foot at the 1 gpm flow rate. At the 4 gpm flow rate, pressure drop is 
0.525" of water per linear foot.

Therma Trim Model TT I=B=R Approved Water Ratings

0

Capacities in BTU/Hr. per Linear Foot with 65 F Entering Air

Average Water Temperature ( F)

0

Water Flow Rate

Lbs/Hr

500

2000

1
4

170

180

190

200

210

220

510

540

580

610

650

690

710

750

780

820

850

900

GPM

Dimensions

Dimensions

8

2-25/32

2

-9

/1

6

2

1

-1

/4

1-11/32

-

/

2

1

1

3

3

1-3/8