Weil-McLain
500 Blaine Street
Michigan City, IN 46360-2388
http://www.weil-mclain.com
550-110-762/0400
Support bare tubing
Place return pipe in
cradle provided by
bracket, as shown.
Support bare supply
tubing from bracket
using wire hangers,
(not supplied).
Holes for risers & connectors
Drill 1½" holes for risers or connectors
Solder elements to risers
and to any additional
tubing that may be
required.
When attaching radiant tubing,
solder connectors and let cool
before attaching tubing. Follow all
tubing manufacturer's instructions.
1C\,
" from wall
1C\,
" from wall
2 >\zn
" above
finished floor
Install damper
Place open end of
damper onto bracket
half rounds.
Press down and inward
to snap onto bracket.
a
b
Install front cover
Hook bottom lip of
front cover under
lower bracket arm
as shown.
If cover does not fit
snugly, bend lower
bracket arm down
and reinstall front
cover.
a
b
Lift the front cover
until top lip of cover
snaps over top prong
of bracket.
Install element
Place element on
brackets as shown.
Assemble multiple
elements by soldering
the male end on one
element into the female
end of another.
For horizontal runs of
more than 30 feet,
install expansion
joints.
Ratings
Ratings
Notes:
Notes:
I=B=R approved water ratings are based on the active (finned) length and
include the 15% addition for heating effect allowed by the I=B=R Testing
and Rating Code for Baseboard Type of Radiation. The active length is 3"
less than the enclosure length. Ratings apply to the assembly with the
damper installed and adjusted to the normally open position.
The heating elements are constructed of 3/4" nominal copper tubing
expanded into 1 7/8" x 2 11/32" aluminum fins, which are spaced 67 to the
foot; fin thickness is .008". Elements are unpainted.
Use of I=B=R ratings at the 4 gpm flow rate is limited to installations in
which the water flow rate through the baseboard unit is equal to or greater
than 4 gpm. Where the water flow rate is not known, the I=B=R ratings at
the standard flow rate of 1 gpm must be used. Flow rates exceeding 6
gpm should be avoided because of possible noise.
Pressure drop through Therma Trim Baseboard is 0.047" of water per
linear foot at the 1 gpm flow rate. At the 4 gpm flow rate, pressure drop is
0.525" of water per linear foot.
Therma Trim Model TT I=B=R Approved Water Ratings
0
Capacities in BTU/Hr. per Linear Foot with 65 F Entering Air
Average Water Temperature ( F)
0
Water Flow Rate
Lbs/Hr
500
2000
1
4
170
180
190
200
210
220
510
540
580
610
650
690
710
750
780
820
850
900
GPM
Dimensions
Dimensions
8
2-25/32
2
-9
/1
6
2
1
-1
/4
1-11/32
-
/
2
1
1
3
3
1-3/8