manualshive.com logo in svg
background image

WS 10
Weighing indicator

USER MANUAL

Edition:10052001A

Содержание WS 10

Страница 1: ...WS 10 Weighing indicator USER MANUAL Edition 10052001A ...

Страница 2: ... and Maintain of the indicator is prohibited by Non professional staff Please make sure the weighing display have good ground in using The indicator is the static and sensitive equipment cut off the power during electrical connections internal components touched by hand is prohibited and please take the measure of anti static ...

Страница 3: ...int format S N G W N W Tare Date Time 1 2 Technical parameter AC power AC100 250V Operation temperatur 10 C 40 C Operation humidity 90 RH Storage temperature 40 C 70 C Accuracy class 6000 e Resolution display 30 000 ADC 2 000 000 Zero stability error TK0 0 1μV K Span stability error TKspn 6 ppm K Sensitivity internal 0 3 μV d Input voltage 30 30mV DC Excitation circuit 5 VDC 4 wire connection Maxi...

Страница 4: ...e platter loosen the shipping screws located at each corner of the platform Three full turns of the screws is necessary The scale will not function properly if the shipping screws are touching the top sub assembly 3 Attach the column to the underside of the bottom frame by using the 4 hexagon head screws supplied On certain models choose which side of the weighing platform will better suit your ne...

Страница 5: ...1 3 Drawing ...

Страница 6: ...t low voltage resulted from self leakage of battery 2 When the battery light is on means low battery 3 The light turns to yellow during charging 4 When the light turns to green means fully charged 5 If the battery is not used for a long time take it out to avoid leakage 1 4 Battery instruction ...

Страница 7: ...2 Basic Operation 2 1 Keys LED Instruction Weighing data kg kg lb lb Hold Data hold Gross Gross weight Net Net weight Tare tare ...

Страница 8: ... G W after 3 seconds back to N W automatically Counting Counting operation Kg lb Convert Convert between kg and lb Accumulation 1 Accumulation 2 work together with Print to perform The accumulation function and check the accumulation result Power On Off Press 2 seconds to power on or power off Keys function The weighing data is stable Weight is zero Hi Overload OK Ok Lo Underload Decimal PCS Show ...

Страница 9: ...At tare mode Press TARE key clear the tare weight the indicator will show the gross weight 2 5 Accumulation operation At Zero mode load weight till stable Press go to accumulation mode Total light on display n 001 and then display loaded weight unload the weight back to zero load the second weight again till stable Press display n002 then display the second loaded weight Repeat Check the accumulat...

Страница 10: ...me format There are two different hold functions Peak hold function and data hold function the setting is different accordingly C11 3 Automatic hold function C11 0 close hold function 1 At weighing mode load the weights on the platform scales Press Count the indicator show PCS 0 press Zero key input the quantity and press Print to confirm it 2 Load the goods on the platform scales and then the ind...

Страница 11: ...h CAL is off press the PRINT hold it and then press HOLD enter C08 39 setting 2 Take out the sealing screw on the back of indicator then press CAL at the SPAN position as below press PRINT hold it and then press HOLD key enter C01 C39 setting The key functions in setting Enter Up Down Power switch Exit setting Exit Save ...

Страница 12: ... required graduation example graduation 5 C03 5 5 press press press or C04 0100 00 0100 00 Max capacity Example max weighing 100kg 0100 00 6 press press press press C05 C05 0 C05 1 CAL 9 0000 00 Zero calibration Option 0 No need zero calibration 1 Need zero calibration Calibration zero please choose 1 and ensure scale is empty and stable light is on Ensure zero calibration countdown till show 0 00...

Страница 13: ...Application function parameters setting chart 07 1 07 0 C07 Function Setting Item Parameters setting and Instruction Warning tone C08 warning tone Option 0 close warning tone 1 open warning tone Automatic power off C09 Automatic power off Option 0 Close auto power off 10 Power off automatically if no change within 10 minute 30 Power off automatically if no change within 30 minute 60 Power off auto...

Страница 14: ...in the max capacity limit C14 Lower Limit Alarm Value Inner Code Display C15 Check inner code Enter C15 to check the inner code Date and Time C16 Date Enter C16 you can set the date from left to right year month day C17 Time Enter C17 you can set the time from left to right hour min sec Communication Setting C18 Serial interface data output method Option 0 Close serial interface data output 1 Cont...

Страница 15: ...ng C22 Automatically Zero TrackingRange Options 0 Close zero tracking 0 5 0 5d 1 0 1 0d 2 0 2 0d 3 0 3 0d 4 0 4 0d 5 0 5 0d Note 1 d Division 2 The zero tracking range can not bigger than manual zero range C23 Automatically zero tracking time Options 0 Close zero tracking time 1 1 second 2 2 seconds 3 3 seconds Overload Range C24 Overload Range Option 00 Close overload range 01d 99d Remark d Divis...

Страница 16: ... filter strength Note Set dynamic filter strength carefully the No is bigger more stable if the loaded weight moves slightly The setting is less than 3 Noise Filter C29 Noise Filter Option 0 Close noise filter 1 1 Digital filter strength 2 2 Digital filter strength 3 3 Digital filter strength Print Time and Date C30 Print time and date C30 0 yy mm dd C30 1 mm dd yy C30 2 dd mm yy C30 3 yy mm dd An...

Страница 17: ...ong connection with load cell 3 Load cell has quality issue 1 Reduce the weight 2 Check load cell connection 3 Inspect load cell Check the input and output nnnnnnn 1 Calibration is off 2 Wrong connection 3 Load cell has quality issue 1 Check scale feet to see if they are level 2 Check load cell connection 3 Checking load cell check input and output resistance ERR1 During calibration not input the ...

Страница 18: ...RINT then press TOTAL to exit saving setting All parameter will go back to default Note Do not restore default parameter if you are not professional ERR3 During calibration the input signal is negative 1 Check the connection 2 Check load cell for problems 3 Recalibration if still wrong change the PCB ERR4 During calibration the signal is unstable After the platform is stable start calibration ERR5...

Страница 19: ...urn the prod uct to The Manufacturer freight and insurance prepaid for repair replacement or credit at The Manufacturer option Any product repaired or replaced under the foregoing warranty shall be shipped back to customer freight and insurance prepaid The sole and exclusive remedy in the event of any breach of the fore going warranty shall be for the original purchaser to return the prod uct to T...

Отзывы: